Link Wiring Detail: Link B (C to C, + to +, - to -)
Lutron cable GRX-CBL-46L
or equivalent
Power panel
To panels where Link B controls
circuits. A Lutron LT-1 (link
LT-1
terminator) should be used to
terminate Link B at the last panel.
Typical Wiring: DMX to Link B (2Link™ only)
Wires must be daisy chained and capped off
at both ends of Link B.
To next
panel
1 2 3 4
D
Data A OK
1 2 3 4
S
ELECT
Circuit selector in the panel
DMX Cable Wiring Table
DMX Cable Type
Belden 9729/89729:
Lutron GRX-CBL-DMX-250/500:
*Wire in daisy-chain configuration as follows: C to C, + to +, and – to –.
6 GRAFIK Eye
4000 Series Control Unit Installer's Guide
®
5
C
D
Power OK
Data B OK
Link Link
A B
D
5
C
D
C
IRCUIT
1
2
Circuit
Wire
(2) drain/shield
white
black
black
red
drain/shield
white
black
green
red
SSA
SSARET
2
1
3 4 3 4
OUT
IN
GRAFIK Eye control unit
STAGEBOARD
RECEPT ACL E
NT-DMXJ-
IN-WH
Cable
recommended
by stageboard
manufacturer or
from Lutron as
GRX-CBL-DMX-
250/500.
C 1
– 2
+
3
4
STAGEBOARD
RECEPT ACLE
5
DMX+ (Pin 3)
Common (Pin 1)
1 2 3 4
D
5
Data A OK
Link Link
A B
From
1 2 3 4
5
D
Circuit Selector
S
C
ELECT
IRCUIT
C
+
Circuit
–
No Connect
No Connect
C
+
–
No Connect
No Connect
To additional control units,
wallstations, panels, or control
DMX512 Stageboard
on Link B
DMX– (Pin 2)
C
D
Link B as
DMX-512
Power OK
Data B OK
To DMX Jack
C
D
(Pin #)
1
C (1)
2
+ (3)*
– (2)*
– (4)
+ (5)
C (1)
+ (3)*
– (2)*
– (4)
+ (5)
interfaces
C 1
– 2
+
3
4
5
R