Set-up the unit
B
W A R N I N G
Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond.
• Never operate this unit in a swimming pond.
N O T E
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear
and will require earlier replacement.
Remedy:
• Thoroughly clean the pond or pool before installing the pump.
• Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being
drawn into the pump.
• Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely covered
with water.
Commissioning/start-up
C A U T I O N
Risk of injury due to fast rotating components.
A temperature monitor switches the unit off automatically in the event of overload and on again once it has
cooled down.
• Isolate the unit before starting any work.
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
• Do not connect the unit to a dimmable power supply.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (Envi-
ronmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.
Adjustments
D, E
Setting the spray pattern and flow rate:
• Adjust the flow regulator so that the nozzle produces the desired spray pattern.
• Adjust the flow regulator to achieve the desired flow rate for the water course.
- EN -
15