Establishing a connection to the WIFI router (router/cloud mode)
Prerequisite:
• The range of the WIFI connection between the router and InScenio FM-Master EGC can span a distance of up to
80 m provided there is unobstructed signal transmission and no sources of interference.
Connection via WPS by pressing a button
A secure connection is established with WPS (WIFI Protected Setup) by pressing a button on the WIFI-Router and on
the FM-Master EGC.
• It is not necessary to enter the SSID and password.
• The WIFI router must support WPS.
How to proceed:
On the router:
1. Press the WPS button on the router to activate WPS.
– Follow the information given in the router operating instructions.
– WPS is only active for a limited time. Activate WPS on the InScenio FM-Master EGC during this time.
 J
On the InScenio FM-Master EGC:
2. Insert the service pin into the opening between the two top sockets until you feel a resistance. The pin is in contact
with the service button.
3. Press the service button briefly (max. 2 seconds) to activate the WPS.
– The LED is lit green and flashes fast.
– The WPS remains active for 2 minutes.
– The connection is established when the green LED flashes slowly (2 seconds on, 1 second off).
On the smartphone/tablet:
4. Establish a connection to the WIFI router.
5. Start the "OASE Easy Controlʺ app.
– InScenio FM-Master EGC can now be controlled using the "OASE Easy Control" app.
Establishing a direct WIFI connection (access point mode)
The range of the WIFI connection between the FM-Master and your smartphone/tablet can span a distance of up to
80 m provided there is unobstructed signal transmission and no source of interference.
• The network name (SSID)  and standard password  are specified
on the adhesive label next to the unit type plate on the FM-Master
EGC.
• The connection is encoded and protected by a password.
– Recommendation: Change the password when starting the de-
vice up for the first time to prevent access to the FM-Master EGC
by unauthorised persons.
• The last six characters of the network name (SSID) "Oase FM-Master <xxxxxx>" are specific to the device and are
preset.
• The InScenio FM-Master EGC has the password "oase1234" in its factory default setting.