Possible incorrect use
The following restrictions apply to the unit:
• Not suitable for salt water.
• Not suitable for drinking water.
• Do not use for long-term operation (e.g.
continuous recirculation of the water in
a pond).
• Do not use in conjunction with chemi-
cals, foodstuff, easily flammable or ex-
plosive substances.
• Do not connect to the drinking water
supply.

INSTALLATION AND CONNECTION

Connecting the pressure hose
An optimum flow rate is achieved with a
hose inside diameter of 25 mm (1").
How to proceed:
 B
1. Remove the protection cap.
2. Connect the pressure hose and adapter
to the connection on the pressure side.
– Recommendation: Use a quick-re-
lease coupling.
14
ProMax Pressure Automatic 5500/5, 6000/8, Well Automatic 3000/15, 6000/8
Installing the pump in a bored well or
shaft
 C
• Attach the fixing rope with a double knot
to the lugs and lower the pump into the
bored well or shaft.
• Use the fixing rope to fix the pump at a
height of at least 1 m above the bottom
of the well or shaft.
– This prevents it from drawing in dirt
particles.
• Ensure that the screen on the suction
side is at least 150 mm below the sur-
face of the water.
• Do not carry the pump by its power con-
nection cable.
• From a well or shaft depth of 5 m, fix the
power connection cable to the fixing
rope at a distance of 5 m from the pump
(strain relief).
Vertical installation of the pump with
the stand
(Only
ProMax
Pressure
5500/5, 6000/8)
The pump can be vertically installed with
the stand in a tank or well.
• Ensure that the screen on the suction
side is at least 150 mm below the sur-
face of the water.
• If the water contains sand and/or is
soiled, install the pump in a raised posi-
tion or use ProMax Floating Intake
(57772).
How to proceed:
 D
1. Push the mounting feet onto the stand.
2. Undo the Allen screws until the opening
of the stand is wide enough to fit onto
the pump.
3. Push the pump into the stand.
4. Tighten the Allen screws until the pump
is fixed in the stand.