Requirements for electric connection

Safety precaution
1.
Must follow the electric safety regulations when installing the unit.
3.
Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4.
Properly connect the live wire, neutral wire and grounding wire of power socket.
5.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.
7.
If the supply cord is damaged, it must be replaced by the manufacturer, its
8.
The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9.
The appliance shall be installed in accordance with national wiring regulations.
10.
Appliance shall be installed, operated and stored in a room with a floor area
larger than "X"m (see table 1).
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter "refrigerant".
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2.
The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3.
The grounding resistance should comply with national electric safety regulations.
4.
The appliance must be positioned so that the plug is accessible.
5.
An all-pole disconnection switch having a contact separation of at least 3mm in
6.
Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
GWH09QB-K6DNA1C GWH09QB-K6DNB8I
GWH09QB-K6DNA1E GWH12QC-K6DNA1C GWH12YC-K6DNA1A
GWH09ACC-K6DNA1A
GWH09YD-S6DBA2A
GWH12QC-K6DNA1D
GWH18QD-K6DNA1D
GWH18YE-S6DBA2A
GWH24QE-K6DNC2C
GWC24ACE-K6DNA1A
2
Air-conditioner
GWH12YD-S6DBA2A
GWH18QD-K6DNC2C GWH18YD-K6DNA1A
GWH24QE-K6DNA1C
GWH24YE-K6DNA1A
GWH09YC-K6DNA1A
GWH18QD-K6DNA1C
GWH24YE-S6DBA2A
GWH24QE-K6DNA1E
13
air switch.
Air switch capacity
10A
16A
25A