SICK Stsndart IN4000 Instrucciones De Servicio página 59

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operating Instructions
IN4000 Standard
WARNING
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8010934/YTC9/2016-04-01
On safety
Note on the classification of the device in compliance
with EN 60 947-5-2:
• The IN40-D0101K safety switch complies with the
classification I1C40SP2M or I2C40SP2M
depending on the installation.
• The IN40-D0303K safety switch complies with the
classification I2A18SP2M.
• The IN40-D0202K safety switch complies with the
classification I2A30SP2M.
• The IN40-D0304K safety switch complies with the
classification I1A18SP2M.
Safety switches are not allowed to be bypassed,
turned away, removed or made ineffective in any
other manner. Their contacts must not be bridged.
Please observe the installation features as per
EN ISO 14 119.
Damaged devices must be replaced.