CONNECTING THE BATTERY CHARGER
The unit is set up to provide for automatic
battery recharging. If this function is to be
used, proceed as follows.
Use a cable of the section indicated in the ta-
ble, and connect it to the relevant terminal on
the generator and to the positive terminal of
CONNECTING THE FUEL INDICATOR
Only use the indicator connection if there is a
fuel level probe in the tank used for the gen-
erator.
CONNECTING THE BATTERY
To start the generator it is necessary to use a
12VDC battery, with a minimum capacity of
60Ah.
Use regulation, sheathed cables, with the
section indicated in the table, and follow the
working order given below:
First connect the positive cable (+ ) of the bat-
tery to the terminal marked with the symbol
"+ " on the generator.
ELECTRICAL CONNECTION TO THE EXTERNAL NETWORK
Important
To use electric power from the external
network, follow the instructions given be-
low with care.
The on board electrical system must be fitted
with a relay or switch (e.g. Dometic switch
cod. AG113, available on request) to prevent
damage to the generator when the external
power supply network is connected; in this
case, it is suggested that the generator be
connected in such a way as to give it priority
with respect to the external network.
The electrical connection must be made in
compliance with current laws in the country of
use.
the battery to be charged.
If the battery to be charged is not the one
used to start the generator, the negative ter-
minal of that battery must be connected to
the generator mass point.
Connect the proble cable (e.g. float) to the
relevant terminal (see figure above).
Then connect the negative cable (-) of the
battery to the terminal marked with the sym-
bol "-" on the generator.
Protect the connections with specific grease.
It is advisable to use a 100A fuse, series fit-
ted in the vicinity of the starter battery posi-
tive terminal, so as to protect the unit system.
For proper installation by the end user, it is
recommended that you request the technical
assistance of the dealer or a specialist tech-
nician.
For the 230 V, use an approved cable with
the section indicated in the table. For connec-
tion of the Dometic switch cod. AG113 refer
to the instructions and diagram on the follow-
ing pages.
- 21 -