STARTING AND STOPPING THE UNIT
Proceed as indicated.
Starting
1 -Press the switch (C)
GB
to enable the power
supply to the controls.
2 -When the display (G)
indicates "GEN OFF",
press the button (D)
to start the unit.
Important
When the unit starts up
for the first time the wa-
ter pump is empty. Keep on carrying out
the start-up operation for 4/5 seconds un-
til the water pump starts to take in sea wa-
ter (priming).
Stopping
1 -Press the switch (C) to turn the unit off.
PROLONGED INACTIVITY OF THE UNIT
In the event of prolonged inactivity of the unit,
a series of operations must be carried out to
guarantee proper operation when it is used
again.
– Drain the water circuit completely.
– Disconnect the battery.
– Turn the safety switch to the "0" (OFF) po-
sition
G
C
D
To restore the unit to operation after a period
of prolonged inactivity it is recommended that
you:
– Change the engine oil (see "Changing en-
gine oil" ).
– Change the fuel filter (see "Changing the
fuel filter").
– Change the sacrificial anode (see "Chang-
ing the sacrificial anode").
- 24 -
IDM - 40200701600.tif
User manual