GB
For -E97A:
-
Brown cable 0301 is connected to -K68A:1
-
Brown cable 0302 is connected from -K68A:1 to
-E97A:L1.
-
Black cable 0303 is connected to -K68A:3
-
Black cable 0304 is connected from -K68A:3 to
-E97A:L2.
-
Grey cable 0305 is connected to -K68A:5
-
Grey cable 0306 is connected from -K68A:5 to
-E97A:L3.
-
Brown cable 0307 is connected from -E97A:T1 to
-K68A:2.
-
Black cable 0308 is connected from -E97A:T2 to
-K68A:4.
-
Grey cable 0309 is connected from -E97A:T3 to
-K68A:6.
For -E97B:
-
Brown cable 0310 is connected to -K68B:1
-
Brown cable 0311 is connected from -K68B:1 to
-E97B:L1.
-
Black cable 0312 is connected to -K68B:3
-
Black cable 0313 is connected from -K68B:3 to
-E97B:L2.
-
Grey cable 0314 is connected to -K68B:5
-
Grey cable 0315 is connected from -K68B:5 to
-E97B:L3.
-
Brown cable 0316 is connected from -E97B:T1 to
-K68B:2.
-
Black cable 0317 is connected from -E97B:T2 to
-K68B:4.
-
Grey cable 0318 is connected from -E97B:T3 to
-K68B:6.
8. Operation is connected.
-
Existing brown cable 066 is moved from -K68A:A1
to -E97A:A1.
-
Brown cable 0319 is connected from -E97A:A1 to
-E97A:22.
-
Brown cable 0320 is connected from -E97A:21 to
-K68A:A1.
-
Existing brown cable 023 is moved from -K68B:A1
to -E97B:A1.
-
Brown cable 0321 is connected from -E97B:A1 to
-E97B:22.
-
Brown cable 0322 is connected from -E97B:21 to
-K68B:A1.
-
Blue cable 0324 is connected from -K68B:A2 to
-E97A:A2.
-
Blue cable 0323 is connected from -E97A:A2 to
-E97B:A2.
9. Setting ramp times for -E97A & -E97B.
-
RAMP UP = 0,7 sec
-
RAMP DOWN = 0 sec
-
INT.TORQUE = 0 %
8
0,4
RAMP UP
0,1
0,4
RAMP DOWN
0
25
INT.TORQUE
0
MSR 60
E97A/B
0,7
L1
L2
1,0 sec
A1
A2
0,4
0,7
RAMP UP
0,1
1,0 sec
0,4
RAMP DOWN
0
1,0 sec
25
1,0 sec
INT.TORQUE
0
70 %
P1 P2 11 21 22
50
T1
T2
70 %
L3
0,7
0,7
50
T3