Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Notes:
- Major pressure differences between hot and cold
water supply should be avoided.
- To be installed according to local codes and
regulations.
- Tuis faucet is not intended for the use with portable
appliances.
Installation
Flush pipes thoroughly.
Installation and connection, see fold-out page III,
figs. [1], [2] and [3].
Refer to the dimensional drawing on fold-out page I.
1
8.3 L/min or 2.2 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - RH
hot - LH
English
Connect spray hose with handspray (31 735 /
31 771), see fig. [3].
(Do not use additional seals.)
1. Mount spray holder (A) to deck.
2. Insert spray hose complete with handspray (B) from
above through the spray holder.
3. Connect spray hose (C) to swivel connection of the
faucet.
Open cold and hot water supply and check
connections for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Shut off cold and hot water supply!
I. Ceramic cartridge, see fold-out page II.
Unscrew the ceramic cartridge (45 882 / 45 883)
using a 17mm socket wrench.
Observe the different replacement part numbers of
the headparts.
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 954).
III. Diverter, see fold-out page II.
1. Pull off cast spout.
2. Pull out the diverter (07 970) and clean.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the
Limited Warranty supplement.