- EN -
Commissioning/start-up
Start-up
Switching on: Switch on pump. Connect transformer to socket.
Switching off: Switch off pump. Disconnect transformer from socket.
Regulate bubbling intensity: Turn stainless steel cap of the light ring (H) or reg-
ulate connected pump.
Remedy of faults
Malfunction
Lunaled does not light up
Light intensity decreases
Irregular 'water' picture
Storage/overwintering
When the unit installation is dry, it can remain in place at temperatures below
zero.
Spare parts
The use of original parts from OASE en-
sures continued safe and reliable opera-
tion of the unit.
Please visit our website for spare parts
drawings and spare parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the
unit via the return system provided for this purpose.
10
Cause
No power supply
Transformer overheated
Transformer defective
Light ring defective
Light ring soiled
Foreign body in Lunaled
Pump soiled
Remedy
Check power supply
Allow transformer to cool down
Replace transformer
Replace Lunaled
Clean light ring (G)
Clean light ring (G)
Clean pump
www.oase-livingwater.com/spareparts