7.2.1 - Level 1 programming (ON-OFF functions)

Table 9 - List of programmable functions in "Programming on power-up" mode
Description
L1
Variable sensitivity
L2
Phototest/Electric lock
L3
Partial opening
At the end of the "Programming on power-up" procedure, the
programming
" mode.
Table 10 - List of programmable functions in "Standard programming" mode
Description
L1
Closing speed
L2
Opening speed
L3
Automatic closure
During normal operation of OVO, the
" mode. For example,
programming
in the first 10 seconds after power-up.
7.2.2 - Level 1 programming (ON-OFF functions)
By default level 1 functions are set as shown in tables 9 and 10, but can be modified at any time as shown in the procedures below. Take
care during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise
the system exits the procedure automatically memorising the changes made up to that time.
• To modify the ON-OFF functions in "programming on power-up" mode:
01. Switch off OVO (for example, by removing the F1 fuse).
02. Press and hold P2.
03. Switch on OVO (for example, by inserting the F1 fuse).
04. Wait for the flashing signal indicating control unit start-up and keep P2 pressed until L1 starts to flash (approx. 6s).
05. Release the P2 key when the L1 LED starts to flash.
06. Press P3 to move the flashing LED to the LED associated with the function to be modified.
07. Press P2 to change the status of the function (short flash = OFF; long flash = ON)
08. Wait 10s to exit the programming mode automatically after the maximum time interval.
NB: points 6 and 7 can be repeated during the same programming phase to set other functions to ON or OFF
• To modify the ON-OFF functions in "standard programming" mode:
01. Press and hold P2 for approx. 3s.
02. Release the P2 key when the L1 LED starts to flash.
03. Press P3 to move the flashing LED to the LED associated with the function to be modified.
04. Press P2 to change the status of the function (short flash = OFF; long flash = ON)
05. Wait 10s to exit the programming mode automatically after the maximum time interval.
NB: points 3 and 4 can be repeated during the same programming phase to set other functions to ON or OFF
Example
This function enables the user to enable or disable the sensitivity with which obstacles are detected.
The factory setting of sensitivity is variable (L1 LED off): greater sensitivity in the case of low motor
force, and less sensitivity where the motor force increases. All with the aim of ensuring optimal
detection precision. Variable sensitivity can be disabled, and 3 "fixed" levels of motor force remain
(L1 LED lit).
This function enables the user to enable output 8 of the terminal board for operation with phototest
or with an electric lock. The factory setting of output 8 is with the "phototest" function enabled (L2
LED off). Alternatively, the output can be programmed on the OVO control unit to control an electric
lock (L2 LED lit).
This function enables either a long or short partial opening interval to be selected. The factory
setting for partial opening is long (approx. 1 m, L3 LED lit). Alternatively, partial opening can be set
to short (approx. 15 cm, L3 LED off).
Example
This function enables the selection of the motor speed during the closing manoeuvre, from 2 levels:
"high" and "low". The factory setting is "high" (L1 LED lit). Alternatively the function can be disabled
to set the "low" speed (L1 LED off).
This function enables the selection of the motor speed during the opening manoeuvre, from 2
levels: "high" and "low". The factory setting is "high" (L2 LED lit). Alternatively the function can be
disabled to set the "low" speed (L2 LED off).
This function enables automatic closure of the door after a programmed pause; the default
Pause Time is set at 30 seconds but may be changed to 15 or 60 seconds. The factory setting is
"semiautomatic" as Automatic closure is disabled (L3 LED off).
,
and
LEDs are lit or off depending on the status of the associated function in "
L1
L2
L3
is lit if the "Automatic closure" function is enabled.
L3
,
and
LEDs indicate the status of the functions in "
L1
L2
L3
also displays the status of the "radio" function
L1
Standard
Standard