7.2.3 - Level 2 programming (adjustable parameters)

Table 11 - List of programmable functions in "Programming on power-up" mode
Input
Parameter
LED
LEDs
(level)
L1
Variable
L1
Sensitivity
L2
L3
L2
Belt recovery
L1
L2
L3
L3
Closure
L1
slowdown
L2
L3
Table 12 - List of programmable functions in "Standard programming" mode
Input
Parameter
LED
LEDs
(level)
L1
Motor force
L1
L2
L3
L2
"Step-by-
L1
step" function
L2
L3
L3
Pause time
L1
L2
L3
All parameters can be adjusted as required without any contraindications, only the "Motor force" setting may require special attention:
• Use of high force values are not recommended to compensate for the fact that the leaf has anomalous points of friction; excessive force
may impair the safety system and damage the leaf.
• If the "Motor force control" is used in support of the system for impact force reduction, the force measurement procedure must be
performed after each adjustment, as envisaged by standard EN 12445.
• Wear and atmospheric conditions influence movement of the gate; force settings should be checked periodically.
7.2.4 - Level 2 programming (adjustable parameters)
By default level 1 functions are set as shown in tables 11 and 12, but can be modified at any time as shown in the procedures below. Take
care during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise
the system exits the procedure automatically, memorising the changes made up to that time.
• To modify the adjustable parameters in "Programming on power-up" mode:
01. Switch off OVO (for example, by removing the F1 fuse).
02. Press and hold P2.
03. Switch on OVO (for example, by inserting the F1 fuse).
04. Wait for the flashing signal indicating control unit start-up and keep P2 pressed until L1 starts to flash (approx. 6s).
05. Release the P2 key when the L1 LED starts to flash.
06. Press the P3 key to move the flashing LED to the "input LED" associated with the parameter to be modified.
07. Press and hold P2during steps 8 and 9.
08. Wait approx. 3s after which the LED associated with the current level of the parameter to be modified will light up.
09. Press the P3 key to move the LED associated with the parameter value.
10. Release P2
11. Wait 10s to exit the programming mode automatically after the maximum time interval.
Points 6 to 10 can be repeated during the same programming phase to modify other parameters.
• To modify the adjustable parameters in "Standard programming" mode:
01. Press and hold P2 for approx. 3s.
02. Release the P2 key when the L1 LED starts to flash.
14
Value
Description
High
When variable sensitivity is enabled, it can be set to three different activation
thresholds. "High" variable sensitivity is most suited to small, correctly
Medium
balanced doors.
Low
No recovery
Adjust belt recovery limit Once the door has closed completely, a brief opening
manoeuvre is then performed which can be adjusted using this parameter.
Minimum recovery
Maximum recovery
Short
Controls how long closure slowdown takes.
Average
Long
Value
Description
Low
Sets the maximum force generated by the motor to move the door.
Medium
High
Open - stop - close -
Adjusts the sequence of commands associated with the "Step-by-step"
open
input or the 1st radio command (see tables 7 and 8).
Open - stop - close - stop
Apartment block
15 seconds
Adjusts the pause time, i.e. time before automatic re-closure. Is effective
only if automatic closure is enabled.
30 seconds
60 seconds