MAG
1 Designated Use
2 Technical Data
Ambient temperature of welding
Transport and storage
Relative humidity
Tab. 1
Temperature
Type of voltage
DC polarity of the electrodes
Type of use
Wire types
Shielding gas
(DIN EN ISO 14175)
Voltage rating
Protection type of the machine
side connections (EN 60 529)
Tab. 2
General torch data (EN 60 974-7)
Type
Type of
cooling
RBC 61GD
air
RB 610D
liquid
Tab. 3
Product-specific torch data (EN 60 974-7)
The MAG hand operated welding torches are used in industry and in the trade
for welding using active gases (MAG). They consist of the torch neck with
equipment parts and wearing parts, handle and cable assembly with central
connector. They correspond to EN 60 974-7 and are not considered to be
devices having their own functions. Arc welding can only be carried out in
connection with a welding power supply.
Wire
Load
ED
CO
M21
2
A
A
%
mm
350 320 35
1.0 - 2.0 10 - 20
650 500 100 1.6 - 3.2 10 - 20
For pulse arcs, the load data are reduced by up to 30 %.
- 10 °C to + 40°C
- 25 °C to + 55°C
up to 90 % at 20 °C
Usually positive
Hand-held
commercially available round wires
CO
and M21
2
113 V peak value
IP3X
Gas flow
Cooling
Max. supply
temp.
l/min
°C
40
1 Designated Use
DC
automatic
141 V peak value
IP2X
Flow
pressure
Min.
min. max.
flow
l/min
bar
1.3
2.5
EN - 3
bar
3.5