4 Putting into operation
1
11
10
1
Gas diffuser
2
Torch neck
3
Wire conduit
4
Retaining nipple
Fig. 2
Liner
4.3 Mounting the cable assembly
EN - 6
2
9
5
Nut
6
Central connector
7
Liner
8
Cable assembly
1 Lay down the cable assembly (8) straight.
2 Remove gas nozzle (10), contact tip (9), tip adaptor (11) and gas
diffuser (1) from torch neck (2).
3 Unscrew nut (5) from central connector (6).
4 Slide liner (7) through the wire conduit (3) up to the retaining nipple (4).
5 Screw in nut (5) by hand.
6 Cut off the excess length of the liner (7) flush with the torch neck (2) and
pull out the liner (7).
7 Sharpen the spiral guide liner beginning to an angle of approx. 40° and
debur the cutting point.
8 Slide sharpened liner (7) through the wire conduit (3) up to the retaining
nipple (4).
9 Screw in nut (5) and tighten it.
10Screw in gas diffuser (1), tip adaptor (11), and contact tip (9) and attach
gas nozzle (10).
1 Combine central connector and central socket at the wire feed unit and
secure them with the connecting nut.
2 Properly mount the connections for water supply/return, shielding gas and
control line plug.
3
8
9
10 Gas nozzle
11 Tip adaptor
7
Contact tip
MAG
4
5
6