Roll the blower unit 90° so that fan blade
5
openings are facing out the back of the oven.
Before Rolling
Back of
Oven
Locate the two "knockout" plates, on the rear
6
oven panel, near the top of the oven.
Using tin snips, carefully cut the web area from
the two holes side-by-side (that secure the
knockouts to the oven). Cut all four webs on both
rear knockouts; this will allow the ventilation fan
airflow to exhaust out the rear of the oven.
CAUTION
edges from the openings after removing the
knockout plates.
Oven Rear Panel
7 Place the blower unit back into the opening.
AFTER:
Fan Blade
Openings
Facing Back
End B
WARNING
Risk of electric shock can
cause injury or death. Do not pull or stretch
the blower unit wiring. make sure the wires
are not pinched..
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of microwave
oven.
49-40650-3
Installation Instructions
After Rolling
Back of
Oven
Be sure to trim the sharp
Snip all 4
webs on each
knockout panel
and remove the
metal knockouts
for rear airflow.
End A
8
Replace the blower plate in the same
position as before with the screws.
9 Insert the tabs on each side of the damper into
the holes at the inside rear of the adaptor.
Attach the exhaust adaptor to the rear of the
10
oven by sliding it into the guides at the top
center of the back of the oven.
Exhaust Adaptor
Slide
exhaust
adaptor into
guides on
oven rear.
Push in securely until it is in the lower locking
tabs. Take care to assure the damper hinge
is installed so that it is at the top and that the
damper swings freely.
Secure the exhaust adaptor to the oven with the
11
two bronze metal screws provided.
Blower Plate Screws
Blower Plate
Back of Oven
Exhaust
Adaptor
Damper
(hinge side up)
Screws
Back of Oven
Locking
Tabs
Guides
17