• Before proceeding to installation, carefully read the following instructions:
• Do not use this component for purposes or applications different from those for which it is expressly studied
and intended.
• If the unit is repaired and/or serviced, use only original components.
The safety edge SC.RES can be used as a safety device for motorised doors and gates. Perpendicular op-
erating force: 50N.
Operating force at 45°: 350N.
This item can operate outdoor and at an ambient temperature ranging from –10° to +50° with a relative max
humidity of 93%.
Max operating range: 50m.
N.B.: Do not put this product in contact with petrol, oils, solvents and acids.
1) Cut the edge at the desired length (fig. 1).
2) For item SC.90 only:
Cut the edge at 45°, possibly using the special scissors (item SC.F).
Insert the "L" nails to create continuity with "C" conductors inserted in the rubber. Fit the "T" cap with
glue on the two edge ends (Fig. 2).
3) To correctly insert the closing cap the base of the edge should be cut for 12 mm. The cut should be ac-
curate to endure a perfectly smooth surface (Fig. 3).
4) Clean the indicated part with abrasive paper (Fig. 4).
5) The closing cap features four pre-formed holes. Choose the desired hole to insert the cable and remove
the plastic with a pointed tool (Fig. 5).
6) Insert the cable through the hole (Fig. 6).
7) Insert the needle contacts in the connector, as shown in the figure, axially positioned with respect to the
wires in the rubber (Fig. 7).
8) Insert the needle contacts of the resistance at the opposite end of the safety edge (Fig. 8).
N.B.: Before sealing the edge with the caps, check that the resistance at the end of the connecting cable
is between 7.8 and 8.6 kΩ.
9) Apply the adhesive tape on the clean surface of the edge and insert the cap immediately, then press on
the cap for about 10 sec.
Important: Apply the adhesive tape on the entire area described, proceeding as follows:
· Turn over the edge of the cap (Fig. 9)
· Apply the glue at the end of the safety edge and apply the cap (Fig. 10)
· Apply the glue on the rest of the surface, unfold the cap edge and make it adhere perfectly to the safety
edge.
Warning: the tip of the connector should be turned towards the outside (Fig. 10).
10) To ensure the complete sealing, apply some glue around the edge of the cap and the hole used (Fig.
11).
11) For the closing cap at the other end of the safety edge, follow instructions given before the assembly of
the resistance cap.
General characteristics of the unit for SC.RES
Power supply: 24Vac ± 10% or 24Vdc ± 10%
Consumption: max 60mA
Output: Normally closed contact
Input: Line with 8.2kOhm ± 5% resistive terminal
Status indicators:
OK: The input line is correctly provided with terminals. The output contact is closed.
O.C.: The input line is open. The output contact is open.
S.C.: The input line is short-circuited. The output contact is open.
Note: In case of power failure, the output contact is open.