APPLICATION OF THE BURNER TO BOILER for mod. COMIST 36
APPLICATION OF THE BURNER TO BOILER (steel fixing flange) for mod. COMIST 72 and 122
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Elastic collar
REMARKS
When tightening the flange, it is important to do it evenly so that the inner faces are parallel between them.
Since the locking system is highly efficient, do not tighten the nuts too much.
During this operation (tightening of the flange locking nuts) keep the body of the burner lifted so that the
combustion head is kept in a horizontal position.
5 - Stud bolt
6 - Locking nut with washer
7 - Nut and washer for fastening the first flange
41 / 132
0006080093 ed2006/07
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Stud bolt
5 - Nut and washer for fastening flange