How to Use Your System (continued)
Top View of Softener Valve
Meter Disc
Hardness
Accuracy Dial
Manual
Hardness Setting
Override Screw
Viewing Window
Hardness Accuracy Dial Settings
Dial Setting
Sumo l
A
B
C
D
E
F
G

Manual Regeneration:

Should you ever need to regenerate your system manually, follow these simple steps: Using a #2 Phillips
screwdriver, push down firmly on the manual override screw (see diagram above) and slowly turn
clockwise, listening for four (4) clicks to start the regeneration. At this point you should hear water begin
to run through the system. If you do not hear water running through the system, the screw has not turned
far enough.
NOTE:
If your hot water tank has refilled with hard water, it may take several days for it to empty and for
your water to feel soft again.
4
Using the Hardness Accuracy Dial:
Sumo's Hardness Accuracy Dial allows you to adjust your system's
regeneration frequency based on inlet water hardness to improve
performance and reduce consumption of salt and water. Your
installer will set the dial according to your water characteristics.
Should your water quality change, you can adjust the set point
to your new water hardness. To do so, first manually regenerate
your softener. (See "Manual Regeneration" at bottom of this page.)
After regeneration is complete, locate the dial on top of your system's
control valve. Press the dial to engage it with the meter gearing, then
turn it in either direction to align the arrow in the window area with
the new setting. Use the chart below to determine your new set point.
Compensated Hardness
Sumo ll
4
5
6
7
10
10
12
15
15
20
20
25
35
Gallons Between Regenerations
Sumo lll
Sumo l
5
395
10
260
15
172
20
125
25
99
35
73
50
Sumo ll / lll
760
500
330
240
190
140
90