SW24.T
Controllable actuators
Ref.
Description
EAM2
EKKO 300D linear operator 24 V 3 m 300 kg
EAM3
EKKO 400D linear operator 24 V 4 m 250 kg
EIM1
HIDDY 200D underground operator 24 V 2 m 200 kg
Trimmer function
Trimmer Description
TCA
Automatic re-closing time (adjustable from 2 to 120 seconds, turn the trimmer clockwise to increase the time)
FM1
Power of motor M1 (adjusts the torque of motor M1, turn the trimmer clockwise to increase the force)
FM2
Power of motor M2 (adjusts the torque of motor M2, turn the trimmer clockwise to increase the force)
VS
Slow speed (adjusts the slow speed of both motors, turn the trimmer clockwise to increase the speed)
V
Standard speed (adjusts the standard speed of both motors, turn the trimmer clockwise to increase the speed)
Button functions
Button
Description
PROG
Button for programming the travel
MRX
Button for programming or deleting remote controls
51
Step-by-step command button
DIP-switch functions
Dip
Function
Status Description
OFF
Automatic
DIP 1
closing
ON
OFF
Apartment
DIP 2
block
ON
OFF
DIP 3
Pre-flash
ON
OFF
DIP 4
Input 63 type
ON
OFF
DIP 5
Photo test
ON
OFF
DIP 6
Output 12
ON
OFF
Safety edge
DIP 7
type
ON
OFF
DIP 8
Rapid closing
ON
OFF
DIP 9
Hammering
ON
OFF
Motor with/
DIP 10
without encoder
ON
LED functions
LED
Status
OFF
PWR
ON
2 blinks
3 blinks
4 blinks
5 blinks
6 blinks
PRG
(or flashing light)
7 blinks
8 blinks
9 blinks
10 blinks
11 blinks
6
Automatic closing off
Automatic closing on
Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with inputs
51 (step-by-step) and 52 (pedestrian). With automatic closing on (DIP 1 = ON) and the gate open, an additional
step-by-step command (terminal 51 or radio command) renews the pause time, and if input 51 remains engaged,
the control panel suspends the pause count until the input is disengaged (for connecting any coils or a timer)
Apartment block off
Pre-flashing off
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
Input 63 is for internal photocell
Input 63 is for safety edge (see DIP 7 for the safety edge type)
Photo-test function off
Photo-test on: the negative accessory power supply terminal (0) turns off for a few fractions of a second before the
start of movement, so any accessories that require a permanent power supply (e.g. photocell receivers) must get
the negative power supply from an input common (terminal 99).
Output 12 for Courtesy Light (LCO): each time the gate moves, the output remains on for 100 s.
The remote control buttons saved on the second radio channel give a pedestrian command
Output 12 for Auxiliary Radio output: the remote control buttons saved on the second radio channel turn the output on for 1 s
Sensitive edge with normally closed contact
Resistive sensitive edge, normally open contact with balancing resistance of 8.2 K Ohm in parallel
Fast closing off
Fast closing function on: if the closing photocell (terminal 62) is engaged, the automatic closing time is set to 5
seconds when it is released
Hammering function for electric lock off
Hammering function for electric lock on (facilitates the unlocking and resetting the electric lock)
The motors connected are equipped with encoders
The motors connected are not equipped with encoders
Description
Mains power supply not present
Mains power supply present
Photocell test failed (incorrect wiring or photocells busy)
Problem detected in the circuit that activates motor M1
Problem detected in the circuit that activates motor M2
Problem on encoder M1 (encoder M1 damaged or wired incorrectly)
Problem on encoder M2 (encoder M2 damaged or wired incorrectly)
Serious EEPROM error (EEPROM missing or damaged)
Motor timeout (gear motor not engaged or damaged)
Fuse F2 blown
Motor M1 overcurrent error
Motor M2 overcurrent error
EN