LIMITED WARRANTY

KASSEL SANITÄR S.L. warrants that its electronic products will be free of defects in
material and workmanship during normal use for two years from the date the product is
purchased.
If a defect is found in normal use, KASSEL SANITÄR S.L. will, at its discretion, repair,
provide a replacement part or product, or make appropriate adjustments. Damage caused
by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning
will void the warranty. Proof of purchase (original sales receipt) must be provided to
KASSEL SANITÄR S.L. with all warranty claims.
KASSEL SANITÄR S.L. is not responsible for labor charges, installation, or other incidental
or consequential costs other than those noted above. In no event shall the liability of
KASSEL SANITÄR S.L. exceed the purchase price of the product.
If you believe that you have a warranty claim, contact your Kassel Distributor, Dealer
or Plumbing Contractor. Please be sure to provide all pertinent information regarding
your claim, including a complete description of the problem, the product, model number,
the date the product was purchased, from whom the product was purchased and the
installation date. Also include your original invoice.
KASSEL SANITÄR S.L. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL,
INCIDENTAL OR CONSEQuENTIAL DAMAgES. This warranty excludes product damage
due to installation error, incorrect maintenance, wear and tear, battery, product abuse, or
product misuse, whether performed by a contractor, service company, or the consumer.
This warranty does not cover product damage caused by the following:
- Incorrect installation.
- inversions of supply pipes.
- Pressures or temperatures exceeding recommended limits.
- Improper manipulation, tampering, bad or lapsed maintenance.
- Foreign bodies, dirt or scale introduced by the water supply or soap tank.
- use of the soap outside of viscosity specifications.
- Alteration of the original soap/foam dispenser components (including pipes).
14

TROUBLEshOOTING

PROBLEM
INDICATOR
CAUsE
No water
1. Sensor flashes
coming
continuously
out of the
when user's
Low battery.
faucet:
hands are within
the sensor's
range.
2. LED in the
1. Range is too short.
sensor does not
2. Range is too long.
flash once when
user's hands
3. Battery is completely used up
are within the
4. unit is in "Security Mode"*
sensor's range.
5. Sensor is picking up reflections from
the washbasin or another object.
1. Connectors between the electronic unit
and solenoid are disconnected.
2. Debris or scale in solenoid.
3. LED in the
sensor flashes
once when user's
3. The central orifice in the diaphragm is
hands are within
plugged or the diaphragm is torn
the sensor's
4. The water supply pressure is higher
range.
than
8 bar.
5. The water supply pressure is under 8
bars and yet the pressure in the faucet's
body is higher. This situation could be
caused by a sudden increase in the water
supply pressure that the back check
prevents from dropping, even after water
supply pressure drops under 8 bars.
water flow
1. Sensor flashes
from spout
once when user's
does not
hands are within
Debris or scale in diaphragm
stop:
the sensor's
range.
2. LED in the
1. Sensor is dirty or covered.**
sensor does not
flash once when
user's hands
2. Sensor is picking up reflections from
are within the
the washbasin or another object.
sensor's range.
water flow
Filter or aerator is clogged
diminished
* "Security Mode": If the sensor is covered for more than 90 sec. the faucet will automatically shut off
water flow. To return to normal operation remove any blockage.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.
sOLUTION
Replace battery
Increase the range
Decrease the range
The battery must be
replaced.
Eliminate cause of reflection.
Connect the electronic unit
connectors to the solenoid.
unscrew solenoid, pull out
the plunger and the spring
from the solenoid and clean
them. use scale remover
material if needed. when
replacing the plunger, please
make sure that the spring is
in vertical position.
Clean the orifice or replace
diaphragm.
Reduce the supply water
pressure.
Shut off water supply and
unscrew one of the flexible
pipes in order to reduce
the pressure that blocks the
product.
Clean the orifice or replace
diaphragm.
Clean or eliminate case of
interference.
Decrease the range or
eliminate cause of reflection.
Remove, clean, re-install
15

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ksl00495Ksl00496Ksl00480Ksl00490

Tabla de contenido