G
B
SETTINGS AND TRANSMITTER CONNECTIONS
J1
AD+
Feed terminal 12-24V ac/dc
AD-
Feed terminal 12-24V ac/dc
EDGE TX
Feed terminals for mechanical or resistive safety edge
JP1
Safety edge enabling/disabling jumper (standard jumper not inserted for
unconnected safety edge. Disable the jumper if a safety edge is connected)
JP2
Range selector jumper (15 or 30 meters - factory setting 30 m)
JP3
Frequency selector jumper (2 available)
JP4
Power selector jumper (battery or network)
BAT
Alkaline batteries 2 x AA 1,5V (if network power is not used)
DLTX
Green LED function indicator
STANDARD POSITIONS JUMPERS
BAT
JP3
JP2
JP1
NOTE: EACH TIME A NEW JUMPER CONFIGURATION IS USED IT IS NECESSARY TO TURN OFF AND TURN ON POWER TO BOTH THE TRANSMITTER AND THE RECEIVER.
REFERENCE TO STANDARDS FOR AUTOMATIC GATES AND DOORS
The installer must ensure that the installation of the NOVA WIRELESS photocells is performed
only in the presence of further protection as specified by standard EN12453 in 5.5.1.
(general protection requirements).
RIB MAY NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY IMPROPER,
WRONG OR UNREASONABLE USE.
SETTINGS AND RECEIVER CONNECTIONS
J2
JP5
JP6
DLRX
DLTX
JP4
J1
USES
NOVA WIRELESS photocells are technologically advanced and completely meet the active
security demands of all types of automatic opening systems.
They are produced in versions for wall mounting, for mounting to columns of iron or other
smooth material, or on dedicated SUPPORT COLUMNS cod. ACG8039.
12
AD+
Feed terminal 12-24V ac/dc
AD-
Feed terminal 12-24V ac/dc
COM
Contact system
PHOT NC
Contact normally closed
PHOT NO
Contact normally open
EDGE RX
Feed terminals for mechanical or resistive safety edge
Safety edge enabling/disabling jumper (standard jumper not inserted for
unconnected safety edge. Disable the jumper if a safety edge is connected)
Frequency selector jumper (2 available)
Red LED indicating correct power and infrared signal alignment
STANDARD POSITIONS JUMPERS
JP5
JP6
DLRX
J2