MOUNTING
N.B.: Before placing the drilling template (code CVA1940) make sure that the contact surface is clean.
- Affix the plastic bases CPL1312 to the pillars or columns about 40÷60 cm from the ground and at a maximum distance of 10 cm from the conveyance or pressure area or immediately out
of range of any protruding edge.
- After adjustment attach the protective casing CPL1311.
- Install the receiver in a shaded area or in a position not exposed to horizontal sunlight.
- In every case it is advisable to place the photocells at the same height and in line with each other.
- For the correct positioning of the photocells refer to the user installation manual or to standard EN12445.
CONNECTIONS
ATTENTION: In case the receiver led remains lit,
malfunctioning of the main supply is suspected.
It is advisable to connect electrically the photocells
stands to the contact
"A/D-",
to
shield
the photocells from
external noise.
A/D-
Be careful not to
short
circuit
the
system when the
supply phases are
inverted!
Do not perform the connection when
using battery power.
BC08047R
CPL1311
BC08047T
CPL1312
Use H05RN-F cables, with a minimum section of 0,75
mm
2
.
If you exceed the distance of 10 m between photocells
and control panel, the wire section must be increased
to 1 mm
NOTE: It is possible to connect both the transmitter and
the receiver to mechanical or resistive safety edges as
shown in the paragraph "CONNECTION OF MECHANICAL
OR RESISTIVE SAFETY EDGE".
Contact N.C. to connect to terminals
COM-PHOT
13
CVA1940
2
.
Power 12/24V ac/dc to connect to
terminals AD+ AD- on the RIB control
panels
G
B