Device elements
Illustration
1 High pressure hose
2 Cable clamp
3 Pouring vent for fuel
4 Filling level display
5 Storage compartment for nozzles
6 Power supply
7 High-pressure pump
8 Water supply set
9 High pressure connection
10 Storage for spray pipe
11 Water connection with filter
12 Support
13 Carrying handle
14 Cover
15 Power switch
16 Burner
17 Support for spray lance
18 Detergent suction hose with filter
19 Nameplate
20 Cover lock
21 Storage compartment for hoses
22 Push handle
23 Marking of the nozzle
24 Triple nozzle
25 Spray lance
26 Hand spray gun
27 Safety latch of the hand spray gun
28 Lever for trigger gun
Symbols on the machine
High-pressure jets can be dan-
gerous if improperly used. The
jet may not be directed at per-
sons, animals, live electrical
equipment or at the appliance
itself. The high pressure cleaner must only
be used while standing.
Proper use
– Cleaning of: Machines, Vehicles, Struc-
tures, Tools, Facades, Terraces, Gar-
dening tools, etc.
– The high pressure cleaner must only be
used while standing.
– Never leave the appliance unattended
as long as it is in operation.
DANGER
Risk of injury! Follow the respective safety
regulations upon employment at gas sta-
tions or other dangerous areas.
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
Quality requirements for water:
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance and accessories.
If recycled water is used, the following limit
values must not be exceeded.
pH value
electrical conductivity *
settleable solids **
total suspended solids *** < 50 mg/l
Hydrocarbons
Chloride
Sulphate
Calcium
Total hardness
Iron
Manganese
Copper
Active chloride
free of bad odours
* Maximum total 2000 μS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
– 2
EN
6,5...9,5
Conductivity
fresh water
+1200 μS/cm
< 0,5 mg/l
< 20 mg/l
< 300 mg/l
< 240 mg/l
< 200 mg/l
< 28 °dH
< 50 °TH
< 500 ppm (mg
CaCO
/l)
3
< 0,5 mg/l
< 0,05 mg/l
< 2 mg/l
< 0,3 mg/l
7