Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Once the equipment has been assembled,
1.
check that the hoses are connected correctly.
Connect the pressure pot to the compressor.
2.
Turn the regulator wheel (1) anticlockwise.
Before operating the pressure pot, check
3.
that it is completely depressurised (the
pressure gauges show 0).

6. START UP

Disconnect the air hose from the pressure
4.
regulator and connect this to the absorption
and discharge valve. Fill the pressure pot with
the funnel.
5.
Once the pressure pot is full, close the
discharge mouth and absorption and discharge
valve.
Compressor
6.
Disconnect the air hose from the absorption
and discharge valve in order to connect it to
the corresponding pressure regulator.
7.
Turn the pressure regulator (1), checking
that the product comes out of the gun through
the hose. Next, adjust the spraying pressure.
- 15 -
1

Publicidad

Tabla de contenido
loading

Tabla de contenido