Chapter 3. Machine adjustment and setting up

3.1. Adjustment

1
Main switch
2
Button "DECREASE". Reduces set function values
3
Button "INCREASE". Increases set function values
A
Temperature warning light
B
Shrinking warning light
C
Sealing warning light
P
Cycle counter selection button
D
Display. Displays selected functions and relative settings
S
Programme and variable selection button
(figure 3.1. page 66).
PHASE NR. 1 = SWITCHING THE MACHINE ON
Turn the main switch (1) into pos. 1. Before using the machine, wait until the adjusting temperature is reached. This is
signalled by the extinction of the warning light (A).
The display (D) turns on and the number of the currently selected program will appear.
PHASE NR. 2 = PROGRAMS SELECTION
The machine is equipped with 10 selectionable programs (P01÷P10).
Push buttons (2) and (3) to select the number of the program.
PHASE NR. 3 = VARIABLES PROGRAMMING
The number of settable variables will depend upon the programme number (see the following table).
The programming order of the most complete programme (P03) is as follows (if a variable should not be settable, it will
obviously not appear for the other programmes)
1.
Sealing time
2.
Fan delay time after sealing
3.
Shrinking time
4.
Heat chamber temperature
Through button (S) it is possible to look through the variables of the selected program, while through buttons (2) and (3)
the memorized values can be modified. These buttons (2) and (3) act by one digit at a time, but if they are held down for
more than a second, the value will rapidly increase or decrease.
To validate modifications, press button (S) until the number of the program appears on the display.
The fan delay time after sealing can be modified; there is not a LED indicating this variable which is shown with an "r" on
the left display, whereas the two remaining digits will indicate the set up time.
At the end of all variables to be adjusted, the display will show the code of the program just chosen (for example P01).
N.B.: In case during programming the B1 limit switch is being pressed, the unit quits the scheduling, the selected
program is executed and the display shows the number of the program.
PHASE NR. 4 = PERFORMANCE
Once all adjustments have been made, the machine is ready to start working.
Variable
Sealing time
(values expressed in seconds)
Fan delay time after sealing
(values expressed in seconds)
Shrinking time
(values expressed in seconds)
Heat chamber temperature
(the indicated value will correspond
to 180...380°C. 2°C each point)
TABLE OF PARAMETERS ACCORDING TO PROGRAMMES
P1
(sealing only)
Min. = 0,0
Max. = 3,0
Default = 1,3
not settable
not settable
not settable
P2
(sealing and
shrinking)
delayed shrinking
to sealing end)
Min. = 0,0
Min. = 0,0
Max. = 3,0
Max. = 3,0
Default = 1,3
Default = 1,3
not settable
Min. = 0,0
Max. = 1,0
Default = 0,0
Min. = 0,0
Min. = 0,0
Max. = 10,0
Max. = 10,0
Default = 2,5
Default = 2,5
Min. = 50
Min. = 50
Max. = 150
Max. = 150
Default = 100
Default = 100
13
P3
P04, 05, 06, 07,
(Sealing and
08, 09, 10
(sealing and
shrinking)
Min. = 0,0
Max. = 3,0
Default = 1,3
not settable
Min. = 0,0
Max. = 10,0
Default = 2,5
Min. = 50
Max. = 150
Default = 100
GB