Proportional pressure regulator
valve VPPM-...C1 (LCD)
Operating instructions
Original: de
Proportional pressure regulator valve VPPM-...C1 (LCD)
Note
Installation and commissioning may only be conducted by qualified personnel.
The qualified personnel must be familiar with installation and operation of elec­
trical and pneumatic control systems.
1
Product description
1.1 Connections, mounting holes and control sections (in-line valve)
1
4
1
Electrical connecting plug M12
(8-pin)
2
Air connection (2), pressure output
3
Exhaust connection (3)
Fig. 1

1.2 Pneumatic connections (flanged valve)

1
3
1
Duct (2) air, pressure output
2
Duct (1) compressed air, supply
Fig. 2
Festo SE & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
8047963
1508e
[8047959]
. . . . . . . . . . . . . .
6
2
5
3
4
Through-holes for fastening
5
Compressed air connection (1),
supply port
6
Rating plate
port
3
Duct (3) exhaust
1.3 Display and control elements, display symbols
1
4
3
1
Display
2
DOWN key
Fig. 3
2
Application and function
The VPPM-...C1 is intended for regulating pressure proportionally to a specified
setpoint value. A built-in pressure sensor records the pressure at the working line
and compares this value with the setpoint value. If the actual value differs from the
setpoint value, the regulating valve is actuated until the outlet pressure reaches
the setpoint value.
English
Fig. 4
3
Variants of the VPPM-...
Type codes of the VPPM-...
1
VPPM - 6L - L - 1 - G18 - 0L6H -
Pos.
Characteristics
1
Nominal width in [mm]
valve type
2
4
Dynamic response class
3
Valve function
4
Pneumatic connection
– Flange/sub-base
– ISO thread
– NPT thread
5
Standard control ranges:
– Lower pressure value
– Upper pressure value
Alternative control ranges:
– Lower pressure value
– Upper pressure value
6
– Setpoint specification
2
– Switching output
7
Accuracy
Operator unit
1) When an alternative upper and lower pressure value are used, it is not possible to guarantee the overall
accuracy of the VPPM-...C1.
Fig. 5
4
Requirements for product use
Warning
Depending on the functions of the machine/system, the manipulation of signal
statuses can cause serious injury to people or material damage.
• Note that changing the switching characteristics of the switching outputs in
the EDIT mode is effective immediately.
• Activate the password protection (security code) (è Chapter 6 under EDIT
mode).
• The product may only be used in its original status without unauthorised modi­
fications.
• Only use the product if it is in an excellent technical status.
• Comply with all applicable national and international regulations.
• Comply with specified limits (è Chapter 13).
2
3
EDIT key
4
UP key
4
5
6
2
3
Significance
6, 8, 12
F (flange), L (sleeve)
L (Low)
1 (3-way pressure-reducing valve,
normally closed)
F
G18 (1/8"), G14 (1/4"), G12 /1/2")
N18 (NPT 1/8), N14 (NPT 1/4),
N12 (NPT 1/2)
0L (0 bar)
2H (2 bar), 6H (6 bar), 10H (10 bar)
1)
...L (... = value between
0.1...10 bar) e.g. 4L
...H (... = value between
0.1...10 bar) e.g. 9H
O4 (4 ... 20 mA), V1 (0 ... 10 V)
P (PNP), N (NPN)
... (2 %, Standard), S1 (1 %)
... (LED), C1 (LCD)
V1N
-
S1C1
7