4.4. Chuck replacement

If there is a need to replace the chuck, it can be removed in three steps. To reinstall the
chuck, follow the reverse sequence
1
2
3
P.68
PT
ES
EN
FR

4.5. Troubleshooting Chart

In the case of problems not mentioned or problems that you can not solve, contact our
PECOL Technical Assistance Service (page 70).
PROBLEM
POSSIBLE CAUSE
Worn carbon brushes.
Battery is discharged.
The tool will not start or
Battery out of temperature range.
suddenly stops
Electronic overload protection
triggered.
Switch damaged.
Power cable or extension cord (if
applicable) broken.
Charger did not stabilise.
The charger does not charge or
Battery outside the allowed
does not work
temperature range 5°C to 40°C
(Red light flashing).
Faulty battery (green and red
lights flashing).
Charger broken (lights do not
light up).
Thermal protection of the
Low performance of the tool
activated battery
Insufficient tightening.
The drill or installed attachment
spins or comes off the chuck.
Damaged chuck
Machine in overload.
The tool body or battery
Lack of ventilation.
becomes too hot
Bearings damaged.
Sparks are seen through the air
Normal movement of the carbon
brushes with the induced.
intakes
SOLUTION
Refer to PECOL Technical Assistance
Service to replace the brushes.
Check level, if the level light indicates
only red, recharge the battery by
carefully following the instructions
on page 60 to 62. Do not insist on use
until it is recharged.
Wait for the battery temperature to
normalise.
Switch off the machine by the trigger,
correct working conditions and switch
on again. Avoid constant protection
activation.
Refer to PECOL Technical Assistance
Service.
If the power cable of the charger is
damaged, it must be replaced. If it is a
defective extension, replace it.
Wait for 2 or 3 minutes. If it persists,
remove the battery, unplug the
charger, check the cleaning and
tightening of the contacts, and try
again. If it still persists, call PECOL
Technical Assistance Service.
Refer to PECOL Technical Assistance
Service.
Wait for the battery temperature to
normalise.
Tighten chuck as instructed on page
64.
Replace chuck.
Decrease working pressure. Turn
on the machine in dry run for 2 to 3
minutes to cool the engine. Or stop
and wait for the battery to cool down.
Unclog the air passages.
Refer to PECOL Technical Assistance
Service for replacement.
The presence of small sparks in the
brush area is normal and should
only be referred to the Technical
Assistance Service if large.
P.69
FR
EN
ES
PT