Safety Pressure Switch - Promax RG5410A-EXTREME Manual De Funcionamiento Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 92
Advanced Test Products
SAFETY PRESSURE SWITCH (WITH
MANUAL RESET FUNCTION)
The RG5410A-EXTREME is equipped with an internal Safety Pressure Switch. If the
pressure inside the system exceeds 38,5 bar, the system is switched off automatically.
If the Safety Pressure Switch is activated automatically whilst filling a bottle, it could be
caused by the bottle becoming overfilled.
This is a very dangerous situation! You should take steps immediately to reduce the
overpressure and/or to eliminate the overfilling of the bottle.
If the Safety Pressure Switch switches the unit off...
The following precautions should be taken if the Safety Pressure Switch is activated:
a) Suspected overfilling of the recovery bottle
Connect the recovery bottle to another bottle with spare capacity so that the pressure is
reduced to a safe level. This action should also reduce the pressure in the output line
from the RG5410A-EXTREME. Proceed as normal after resetting the Safety Pressure
Switch (see below).
b) Cause of activation of Safety Pressure Switch unknown
1) Check that the recovery bottle is not overfilled.
2) Close the system valves, recovery bottle valves and RG5410A-EXTREME valves.
3) Disconnect RG5410A-EXTREME from flexible pipes.
4) Disconnect RG5410A-EXTREME from the power supply.
5) Open the input and output valves very slowly.
6) Investigate the reason for the failure.
Once activated the Safety Pressure Switch has to be reset manually as follows:
I) Remove the black protection cover to reveal the reset button (see picture below).
II) Reset by pushing the reset button with a tool such as a screwdriver.
III) Replace the cover.
Remove this part in order to
Reset the pressure switch.
14
RG5410A-EXTREME

Publicidad

Tabla de contenido
loading

Tabla de contenido