Ac Voltage Measurements; Ac/Dc Current Measurements - RS Pro RS-9963T Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Digital Multimeter/ English
7. Operating Instructions
Warning: Risk of electrocution. High-voltage circuits, botn AC and DC, are very dangerous
and should be measured with great care.
• Always turn the function switch to the OFF position when the meter is not in use.
• If "OL" appears in the display during a measurement, the value exceeds the range you
have selected. Change to a higher range.
7.1 DC voltage Measurements
Caution: Do not measure DC voltages if a motor
on the circuit is being switched ON or OFF. Large
voltage surges may occur that can damage the
meter.
• Set the function switch to the "DC" position.
• Insert the black test lead banana plug into the
negative COM jack.
Insert the red test lead banana plug into the
positive V jack.
• Touch the black test probe tip to the negative
side of the circuit.
Touch the red test probe tip to the positive side
of the circuit.
• Read the voltage in the display.
4

7.2 AC Voltage Measurements

Caution: Do not measure AC voltages if a motor
on the circuit is being switched ON or OFF. Large
voltage surges may occur that can damage the
meter.
• Set the function switch to "AC" position.
• Insert the black test lead banana plug into the
negative COM jack.
Insert red test lead banana plug into the
positive V jack.
• Touch the black test probe tip to the neutral
side of the circuit.
Touch the red test probe tip to the " hot " side
of the circuit.
• Read the voltage in the display.

7.3 AC/DC Current Measurements

Caution: Do not test 10A current measurements for longer than 30 seconds. Exceeding
30 seconds may cause damage to the meter and/or the test leads.
• Insert the black test lead banana plug into the negative COM jack.
• For current measurements up to 6000μA AC/DC, set the function switch to the μA
position and insert the red test lead banana plug into the μA/mA jack,press mode button
to select AC or DC.
• For current measurements up to 600mA DC, set the function switch to the mA position
and insert the red test lead banana plug into the μA/mA jack ,press mode button to select
AC or DC.
13/12/2017 Version No. 001
13/12/2017 Version No. 001
Digital Multimeter/ English
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

146-9097

Tabla de contenido