Descargar Imprimir esta página

Bosch GRL160DHV Instrucciones De Funcionamiento Y Seguridad página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

50 ft. (15 m)
50 ft. (15m)
4. Mark the laser beam height (center) on the
vertical surface of the wall, as A.
5. Rotate the tool 180°, taking care not to
change its height. The tool should be
positioned with its opposite side facing the
same vertical wall as in step 2. Use the
level (horizontal) Line Dither/Scan position
arrows 23 and 25 to position the laser
beam on the original wall.
Y
50 ft. (15m)
50 ft. (15 m)
6. Mark the height of the laser beam on the
same vertical surface, as B. If B is
positioned at the same height as A,
proceed to step 11. Otherwise, continue to
step 7. The goal of the next few steps is to
position the level laser beam at a height
halfway between A and B
7. Turn off the laser beam and the tool.
Caution: The laser beam must be turned off
and the main power switch in the off position
before proceeding to the next step
8. Insert an Allen wrench into the side
calibration port and locate the calibration
screw. Rotate it clockwise to lower the
beam, or counterclockwise to raise
the beam.
9. Remove the Allen wrench from the
calibration port. Turn on the power, turn on the
level laser beam, then check the height of the
laser beam. Repeat steps 7 and 8 until the
beam is at a height exactly halfway between
A. and B.
Caution: The Allen wrench must be removed
from the calibration port before turning on
the power.
10. Mark this calibrated point on the vertical
surface, as C.
A
*
Y
11. Repeat steps 3-7 to confirm the position of
C, then proceed to step 12.
12. Rotate the base unit 90° and position it
with the front facing the vertical surface.
Mark the height of the laser beam, as D.
B
*
13. Compare the height of D with C. If the
height of D matches the height of C,
calibration is complete. Turn the power
switch to the off position. Reattach the
calibration port covers, then resume
normal operation. If the height of D does
not match the height of C, proceed to
step 14.
14. Turn off the laser beam and power to the
unit.
Caution: The laser beam must be turned off
and the power switch in the off position before
proceeding to the next step.
15. Insert an Allen wrench into the front
calibration port and locate the calibration
screw. Rotate it clockwise to lower the
beam, or counterclockwise to raise
the beam.
-14-
50 ft. (15 m)
50 ft. (15m)
50 ft. (15m)
50 ft. (15 m)
A
C
*
B
C
* D

Publicidad

loading