To reduce risk of electric shock, pull
plug before servicing. This pump has not been
investigated for use in swimming pool areas. pump is
supplied with a grounding conductor and grounding-
type attachment plug. Be sure it is connected only to
a properly grounded grounding-type receptacle.
where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.
12. A ground fault circuit is recommended for use with any
electrical appliance submerged in water. Installation and
all wiring should be performed by a qualified electrician.
13. Make certain power source conforms to requirements of
your equipment.
14. Protect electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking cord. Replace or repair
damaged or worn cords immediately.
15. Do not touch an operating motor. Motors can operate at
high temperatures.
16. Do not handle pump or pump motor with wet hands or
when standing on wet or damp surface, or in water.
Risk of electric shock. If your basement
has water or moisture on floor, do not walk on wet area
until all power has been turned off. If shut-off box is in
basement, call electric company or hydro authority to
shut-off service to house, or call your local fire department
for instructions. Failure to follow this warning can result in
fatal electrical shock. Remove pump and repair or re place.
California proposition 65 warning
This product and related accessories contain
chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm.
dESCRIpTION
This Submersible Sump Pump is designed for home sumps.
Unit is equipped with a 3-prong grounding-type power cord.
The permanent split capacaitor motor is oil filled and sealed for
cooler running. The sleeve bearings on the motor shaft never
need lubrication. The pump includes automatic reset thermal
protection.
Pump water only with this pump.
SpECIFICATIONS
Power supply required .............................................115V, 60
HZ ..........................................................................................
Liquid Temp. Range* ......................... 32° F-77° F (0°-25° C)
Individual Branch Circuit Required ..........................15 Amps
Discharge* .............................................................1-1/2" Slip
* Use 1-1/4" or 1-1/2" rubber coupling and clamps included
with pump.
NOTICE: Not for use in recirculating applications.
NOTE: For model B75-M1, purchase switch separately.
Follow switch manufacturer's instructions for installation.
Switch must be rated to meet code and adequately control
a 3/4 HP, 7.5 amp, 115 volt motor. Be sure sump is large
enough to allow for free operation of switch. Model B75-V1
includes vertical switch.
pERFORMANCE
GPM (LPM) AT TOTAL FEET (m)
5
Model
(1.5m)
CAPACITY GALLONS(L)/MINUTE
B75-M1
100
B75-V1
(378)
INSTALLATION
1. Install the pump in a sump pit constructed of tile,
concrete, steel, or plastic (check your local codes for
approved materials). Pit diameter must be at least 10"
(254mm) for model B75-V1 and 14" (356mm) for model
B75-M1 equipped with a tethered float switch (purchase
switch separately). Do not install the pump on a clay,
earth, or sand surface.
2. Make sure the pit is free of small stones, gravel, and any
other debris which could clog the pump.
3. Make sure that the switch has the maximium possible
clearance from the sump wall, etc.
4. Install the discharge piping. Use rigid piping in any
permanent installation. Cut the piping so that it stops
about 1/2" short of the pump discharge.
Risk of flooding. Make sure the pump
is secured so it cannot move around in the sump. If it
moves, interference between the switch and the sump
wall may prevent the pump from starting or stopping,
causing flooding or damage to the pump.
NOTE the following:
• Use plastic pipe for a rigid discharge pipe installation.
• Do not use ordinary pipe joint compound on plastic
pipe. Pipe joint compound can attack plastics, causing
cracking and failure.
• Keep the discharge piping as short as possible to
reduce friction in the pipe.
• The discharge pipe's diameter should be at least as
large as the diameter of the pump's discharge port.
• A pipe smaller than the port diameter will constrict
the flow, reduce performance, and lead to early pump
failure. A larger pipe may require adapters to fit the
pump discharge.
• Pump has an internal check valve to prevent flow back-
wards through pump when it is shut off.
5. Loosen the coupling clamps and slide the discharge
coupling up the discharge pipe an inch or two. Place the
pump in the sump and slide the coupling down over the
pump discharge (so it holds both the pump discharge and
the discharge pipe). Tighten the coupling clamps. Secure
the discharge line before starting the pump.
6.
hazardous voltage. pump should
always be electrically grounded to a suitable electrical
ground such as a grounded water pipe or a properly
grounded metallic raceway or ground wire system.
do not modify cord or plug or cut off round ground
pin. Install the pump on a 115V/ 60Hz/15Amp individual
branch circuit.
• B75-V1: Both the pump and the switch are supplied
with 3-wire cords with grounding-type plugs. For
automatic operation, plug the switch into the wall outlet
and plug the pump into the switch plug. For continuous
operation, plug the pump directly into the wall outlet.
• B75-M1: The pump is supplied with a 3-wire cord with
grounding type plug. Plug the pump directly into the
wall outlet for manual operation.
2
10
15
20
(3m)
(4.6m)
(6.1m)
84
64
39
(318)
(242)
(147)
No flow
at height
shown
below
25 Ft.
(7.6m)