E N G L I S H
TURNING ON THE DISPLAY BACKLIGHT
In order to avoid the hazard arising from
mistaken readings in insufficient light or poor
vision, please use Display Backlight function.
• Press and hold YELLOW button for over 2 seconds to
turn the Display Backlight on.
• Press YELLOW button again to turn the Display
Backlight off, otherwise it will stay on continuously.
SLEEP MODE
To preserve battery life, the Meter automatically turns
off if you do not turn the rotary switch or press any
button for around 15 minutes.
The Meter can be activated by turning the rotary switch
or pressing the YELLOW, Hz or
display the present measurement value.
To disable the Sleep Mode function, press BLUE button
while turning on the Meter.
GENERAL SPECIFICATIONS
Maximum voltage between any terminals and grounding: 600 V rms
Maximum current measurement of transformer jaw: 1000 A AC rms
continous.
Maximum Jaw Size: 40 mm conductor.
Maximum Display: Digital 3999.
Measurement Speed: Updates 3 times/second.
Temperature: Operating: 5° C to + 35° C (41° F to + 95° F).
Storage: -10° C to + 50° C (14° F to + 122° F).
Relative humidity: ≤75% @ 0 - 30° C; ≤50% @ 31° C - 40° C
Altitude: Operating 2000 m / Storage 10000 m
Battery tipe: The meter: one piece of 9 V (NEDA 1604 or 6F22 or
006P). The jaw opening light: one piece of 1.5 V (AAA)
Battery deficiency: Display
Dimensions (H x W x L): 260 x 104 x 52 mm.
Weight: Approximate 530 g (battery included).
Safety / Compliances: IEC61010 CAT. II 1000 V, CAT. III 600 V
overvoltage and double insulation standard.
Certifications: CE, UL pending.