ACCURACY SPECIFICATIONS
Accuracy: (a% reading + b digits), guarantee for 1 year.
Operating temperature: 23°C + 5°C
Relative humidity: <75%.
Temperature coefficient: 0.1 x (specified accuracy) / 1°C
A.
DC Voltage
Range
400 mV
4 V
40 V
400 V
600 V
Remark:
Input impedance: ≥10MΩ
B.
AC Voltage
Range
4 V
40 V
400 V
600 V
Remark:
Input impedance: 10MΩ Display effective value of sine
wave (mean value response). Frequency response: When <400V: 40
Hz ~ 400 Hz; When ≥400 V: 40 Hz ~ 100 Hz
C.
Resistance
Range
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
Remark:
Open circuit voltage approximate 0.45 V
D.
Continuity Test
Range
400 Ω
Remark:
Buzzer beeps continuous. Open circuit voltage approximate 0.45 V
Resolution
100 µV
1 mV
10 mV
100 mV
1 V
Resolution
1 mV
10 mV
100 mV
1 V
Resolution
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Resolution
0.1 Ω
Accuracy
Overload Protection
± (0.8%+3)
± (0.8%+1)
600 AC rms continuous
± (1%+3)
Accuracy
Overload Protection
± (1.2%+5)
± (1.5%+5)
Accuracy
Overload Protection
± (1.2%+2)
± (1%+2)
± (1.2%+2)
± (1.5%+2)
Accuracy
Overload Protection
Around <70 Ω
E N G L I S H
600 V rms
600 V rms
600 V p
600 V p
43