Figure 4 Locations Of Housing Screws; Closing The Housing; Wiring The 24 Vdc Model - Federal Signal eHorn Instrucciones De Instalación Y Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Maintenance Instructions

Closing the Housing

1. Verify that the cover gasket is in the groove around the
perimeter of the cover.
2. Align the housing with the cover. Note that the FS logo on
the front of the eHorn needs to be oriented correctly with
the arrow on the inside of the cover or the two parts will
not fit together.
3. Tighten the cover screws hand tight, then torque them to
60 in‑lb +/‑ 10 in‑lb.

Wiring the 24 Vdc Model

SHOCK HAZARD: To avoid electrical shock, do not connect wires when the
circuits are energized.
To extend wire for the power connections, use only 12 AWG
to 18 AWG (2.5 mm
connector must be suitably protected to prevent damage. Use
grommets, bushings, and wires ties to protect them from abrasion.
12

Figure 4 Locations of housing screws

Cover Screws (4 Places)
to 1.0 mm
2
Model eHorn
) wire. The external leads and
2