Descargar Imprimir esta página

Kenmore 148.16156210 Manual De Uso Y Cuidado página 14

Parilla a gas de propano liquido
Ocultar thumbs Ver también para 148.16156210:

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions:
1. To connect, push back socket sleeve.
Your grill can be converted to natural gas. The
conversion must be performed by a qualified gas
technician. The following listed Natural Gas Conversion
Kit (sold separately) and 1.33 mm nozzle (provided with
grill) are required for the conversion.
Natural gas conversion kit
Kenmore Model # 10478
(Manufacturer Part No.: S3218AN-KIT)
Naturalgasnozzle1.33rnrn for 16156/16157 Rear
Burner (Provided with gasgrill)
To purchase a Natural Gas Conversion kit call Sears at
1.800.4.MY.HOME ®
Natural Gas Connection Preparation:
1. Turn off gas supply, and then remove cap on gas
supply side.
2. Recommended: Install a shut-off valve on
gas supply side before installing the socket.
3. Socket should be installed by an authorized
technician in accordance with the nationalfuel gas
code (NFPA54/ANSI223.1).
4. Before inserting plug, turn on gas supply and leak
test all connections including the stem of the shut-off
valve and the opening of the socket. For best results,
use an ammonia-free soap & water solution.
Socket
Sleeve_
_-
Plug
2. Insert plug and release sleeve.
3. Push plug until sleeve snaps forward. (Gas will flow
automatically.Failure to connect plug properly to
socket will inhibit gas flow to the appliance.)
Socket
Sleeve
To disconnect
1. Pull Sleeve back. Pull plug out of socket. (Gas is
automaticallyshut off.)
2. Close shut-off valve or turn off gas supply, and replace
dust caps on socket and plug.
Natural Gas
Now that your grill is converted to Natural Gas use, it is
set for 7-inch water column (WC) pressure, and cannot
be used with Propane Gas. Gas pressure is affected by
gas line size and the length of gas line run from the
house. Follow the recommendations in the chart below.
From House to Grill
Distance
Tubing Size
Up to 25 ft.
3/8 in. diameter
26-50 ft.
1/2 in. diameter
2/3 of the run: 3/4 in. diameter
51-100 ft.
1/3 of the run :1/2 in. diameter
Over 101 ft.
3/4 in. diameter
14