Setting DC Ceiling fan 2:
Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
Slide the cover of battery compartment of transmitter to access the DIP switches. This will be transmitter 2.
Change the position of the DIP switches in the remote transmitter 2, so that it will be different to transmitter 1. Fig.12
Install the 12VDC battery in the compartment. Please make sure the polarity of the battery is correct.
Turn on the power to receiver 2. Keep the power OFF to receiver 1. (Each ceiling fan must have its own isolation
switch, so that only the Ceiling fan that needs to be paired with the transmitter will be ON).
Press and hold the SET button of transmitter 2 for 6 seconds within 60 seconds of switching the power to the
receiver of Ceiling Fan 2.
Now the transmitter should be paired with the receiver of ceiling fan 2. Turn ON/OFF or change the speed of the
ceiling fan 2 by the transmitter to check operation.
Note: The pairing of Transmitter and Receiver is not required if only one Ceiling fan is installed. When more
than two ceiling fans are installed near each other, please refer to the instruction above.
Remote Control Buttons
1 - FAN SPEED CONTROL BUTTON:
There are 6 available speeds.
speed, and
VI button is for the fastest speed.
NOTE: WHEN YOU TURN ON THE FAN THE FIRST TIME
OR SWITCH THE MAIN POWER TO THE CONTROLLER,
YOU NEED START THE FAN ON HIGH "
FIRST, AND THEN CHOOSE A LOWER SPEED.
A 5-10 SECONDS IS REQUIRED TO ALLOW THE DC FAN
TO RESPOND TO THE REMOTE EACH SPEED OR FAN
DIRECTION SELECTIONS, AS DC FAN INCORPORATE A
SENSOR CONTROL WHICH CONTROLS THE POWER
TO THE MOTOR.
I button is for the lowest
VI " SPEED
Fig. 10