Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Fan
LIGHT
LIGHT
SWITCH
SWITCH
NIGHT LIGHT
NIGHT LIGHT
SWITCH
SWITCH
FAN
FAN
SWITCH
SWITCH
BLK
BLK
LINE
LINE
WHT
WHT
IN
IN
GRD
GRD
BLACK
BLACK
WHITE
WHITE
BLUE
BLUE
LIGHT
LIGHT
NIGHT LIGHT
NIGHT LIGHT
FAN
FAN
MULTI CONTROL
MULTI CONTROL
(purchase separately)
(purchase separately)
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
BLK
BLK
RED
RED
WHT
WHT
BLK
BLK
WHT
WHT
GRD
GRD
SWITCH BOX
SWITCH BOX
RED
RED
GROUND
GROUND
(green or bare)
(green or bare)
SWITCH BOX
SWITCH BOX
120 VAC
120 VAC
LINE IN
LINE IN
WHT
WHT
BLU
BLU
LIGHT
LIGHT
RED
RED
NIGHT
NIGHT
WHT
WHT
LIGHT
LIGHT
BLK
BLK
WHT
WHT
FAN
FAN
UNIT
UNIT
LIGHT
LIGHT
RECEPTACLE
RECEPTACLE
WIRES
WIRES
FAN
FAN
RECEPTACLE
RECEPTACLE
LIGHT
LIGHT
RECEPTACLE
RECEPTACLE
KNOCKOUT
KNOCKOUT
PLATE
PLATE
FAN
FAN
RECEPTACLE
RECEPTACLE
WIRES
WIRES
RB80L
RB110L Installation Guide
n
3
4
Screw from
Parts Bag