Emerson HF1160BQ02 Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BP7272-4 HF1160.qxp_BP7272 9/10/15 9:44 PM Page 8
The fan must be hung with at least 10' of clearance from
floor to blades (Figure 10).
Your support beam or joist must be secure and capable
of withstanding a load of at least 50 pounds.
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as "Acceptable for Fan Support of 22.7
kg. (50 lbs.) or less".
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
Read and follow instructions carefully. Failure to comply
with instructions could result in risk of fire, electric
shock, fan falling and injury to persons.
Hanger bracket must seat firmly against outlet box. If the
outlet box is recessed, remove wall board until bracket
contacts box. If bracket and/or outlet box are not securely
attached, the fan could wobble or fall.
4.1
Securely attach the hanger bracket to the outlet box using
the two screws supplied with the outlet box (Figure 11).
4. How to Hang Your Industrial Fan
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
AT LEAST
10'
Figure 10
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
Figure 11
8
CEILING
FLOOR
OUTLET
BOX
HANGER
OPENING
HANGER
BRACKET
ANTI-ROTATION
TAB
U.L. Model No.: HF1160-2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hf1160bs02Hf1160ww02

Tabla de contenido