9 Troubleshooting

9.1 General

This chapter describes faults that may occur and how to deal with these faults. If the faults
cannot be dealt with, or if there are other faults, contact your nearest retailer. For contact
information, see the start of the manual.
Fault description
Fault code is shown in HMI.
The machine loses contact
with other units.

9.2 The machine will not start

Error source
Electrical supply
Power supply
Mainboard
Fuse
D004753, 01.01
Cause
One of the machine's alarm
systems has been activated.
The CAN bus signal is
broken.
Cause
Fault on supply, e.g. fuses,
earth fault breakers or
connecting cables
Power supply indication is
not lit
Main circuit board is not lit
Standby LED on the control
panel Panel is not lit
Troubleshooting
Instruction user
For more information see
Warnings and Error
Messages.
Check cable connections on
the connection panel.
Instruction user
Check correct voltage on
incoming phase/phases.
Check miniature circuit
breaker F1.
Check fuse F2, red LED.