Malfunctions

Malfunctions
Blue LED on the mixer tap
is not lighting up
Water does not run when
the sensor is activated
Hot water mode is
not functioning
Cold and/or warm water
is not running
The set water quantity
for filter or hot water is
significantly different
Status LED on the boiler
is glowing orange
46
Possible causes
- Mixer tap is not receiving
electricity
- The volume wheel is at "0"
- Connecting hoses
are kinked
- Connecting hoses are
wrongly attached
- The volume wheel is at "0"
- Filter head is connected in
the incorrect flow direction
- Electronic devices are in
front of the sensor
- The volume wheel is at "0"
- Connecting hoses
are kinked
- Connecting hoses are
wrongly attached
- Malfunctions in
the control box
- System error in the boiler
Error correction
- Connect the power supply unit of the control
box to the mains electricity
- Check the connections on the control box
- Turn the volume wheel and set
an amount > "0"
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
- Turn the volume wheel and set
an amount > "0"
- Check whether the filter cartridge has
been connected against the flow direction,
and change the flow direction
- Remove electronic devices
- Turn the volume wheel and set
an amount > "0"
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
- Unplug the power supply of the control
box for one minute, then connect it to
the mains again
- Unplug the power supply of the boiler for one
minute, then connect it to the mains again