Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INDICATOR LEDS

The indicator LEDs on the frontal panel of the battery will show its operational state as follows:
RUN LED (green)
ALARM LED (red)
SOC LEDs (6
greens)
STAUTUS LED
(green)
TURNING OFF THE BATTERY
To turn off the battery follow these steps:
1. Turn off the inverter.
2. Turn off the battery
3. Within a few seconds, the internal main relay will
cut off and all the LEDs will turn off.
PC COMMUNICATION (OPTIONAL)
Connect the RS232 communication port of the
battery to the computer, the information will display
in 6 different tabs:
1. Realtime monitoring: SOC%, voltage, current,
cycles, capacity and running status, cell balancing
and temperature.
2. Multi monitoring: system message.
3. Parameteres setup.
4. System setup.
5. Export data.
22
MANUAL DE USUARIO BATERÍA DE PINO / BATTERY PINO USER MANUAL
Lighting: System working normal
Flashes every 0,5s: system warning
Lighting: system protection
Lighting: system fault
In charging mode
SOC<16,6%, LED1 flashes every 0,5s.
16,6%<SOC<33,2%, LED1 on, LED2 flashes every 0,5s.
33,2%<SOC<49,8%, LED1, LED2 on, LED3 flashes every 0,5s.
49,8%<SOC<66,4%, LED1, LED2, LED3 on, LED4 flashes every 0,5s.
66,4%<SOC83%, LED1, LED2, LED3, LED4 on, LED5 flashes every 0,5s.
83%<SOC<100%, LED1, LED2, LED3, LED4, LED5 on, LED6 flashes every 0,5s.
In discharging mode
SOC<16,6%, LED1 on.
16,6%<SOC<33,2%, LED1, LED2 on-
33,2%<SOC<49,8%, LED1, LED2, LED3 on.
49,8%<SOC<66,4%, LED1, LED2, LED3, LED4 on.
66,4%<SOC<83%, LED1, LED2, LED3, LED4, LED5 on.
83%<SOC<100%, LED1, LED2, LED3, LED4, LED5, LED6 on
For communication status indication:
- Normal BMS/MPPT/INVERTER communication: the LED is on.
- Abnormal BMS/MPPT communication: the LED is on for 0.5s and off for 0.5s.
- Abnormal BMS/INVERTER communication: the LED is ono for 0.5s and off for 1.5s.
- Abnormal BMS/MPPT/INVERTER communication: the LED is on for 2s and off for 2s
WARNING!
If the battery is not used for a long period of time or if it has any fault,
keep off the power switch.
RS232-6P6C-RJ11
Pin RJ11
Definition
2
NC
3
TX
4
RX
5
GND
www.intipv.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ilfp-1536Ilfp-2560Ilfp-3072Ilfp-3840Ilfp-5120Ilfp-512024

Tabla de contenido