Inverter) - Connections - entrematic Ditec Sector Manual De Instalación, Manutención, Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.2 47E (INVERTER) ELECTRONIC CONTROL PANEL - CONNECTIONS
47E
Command
1
2
N.O
1
3
N.O
1
4
N.O
41
40
N.C
1
8
N.C
1
9
N.C
1
9
N.O
1
20
N.O
1
11
N.C
1
12
N.C
1
13
N.C
Output
+
1
-
0
LAMP
RF
CNT
100Ω 32w
-F
+F
U W V
M
3 ~
0DT827 2014-06-13
Function
Automatic closing
Permanently closing the contact enables automatic closing.
Opening
The closure of the contact activates an opening operation.
Closing
The closing manoeuvre starts when the contact is closed.
Reversal safety
Opening the safety contact triggers a reversal of the movement (reopening)
device
during a closing operation.
Reversal safety
Opening the safety contact triggers a reversal of the movement (reopening)
device
during a closing operation.
Stop
Opening the safety contact stops the current operation.
Non-pulse
Permanently opening the safety contact enables the operation by non-
command
pulse command
In this state, the opening (1-3/1-20) and closing (1-4) controls function only
if held in the pressed position, and the automation stops when the controls
are released.
All safety switches, the step-by-step control and the automatic closing
function are disabled.
Partial opening
The closing of the contact activates a partial opening operation of the
duration set with the RP trimmer.
Closure limit switch
The opening of the limit switch contact stops the closure operation.
Limit switch
The opening of the limit switch contact activates the slowdown in opening.
slowdown
Opening limit switch The opening of the limit switch contact stops the opening operation.
Value
Accessories power supply.
24 V = / 0,5 A
Power supply output for external accessories, including automation status
lamp.
Flashing light (LAMP).
230 V~ / 50 W
Activated during opening and closing operations.
Enabling RF brake resistance.
Resistance is enabled during all operations.
Electric motor brake.
24 V = / 0,5 A
The output is active for the duration of both the opening and closing operation.
230 V~ / 6 A
Three-phase motor.
INPUTS
description
OUTPUTS
description
- 34 -

Publicidad

Capítulos

Tabla de contenido
loading