Welding Data Files for Welding Data Recording
A welding data file is created for each welding process. A welding process begins when the clamping arm is acti-
vated and ends when the clamping arm is released.
A weld seam consists of at least one welding process. It can also consist of several welds, if this is necessary during
the welding process.
The name of the welding data file consists of the device identifier, date, time, a serial number, and optional file
name affix.
The serial number starts with 001 at the start of each new day and can be a maximum of 999.
Welding without Data Recording
In order to weld without data recording, data recording must be switched off in the Setup menu.
• In the function display (33), rotate the "e-Drive"
• Press "e-Drive"
• Select "Welding Data Record." in the "Setup" menu by rotating the "e-Drive"
• Rotate the "e-Drive"
Rotate the "e-Drive"
• In the function display (33), rotate the "e-Drive"
Power Supply Interruption
Condition of device prior to
power supply interruption
The drive and heating are switched on
(welding process and data recording).
The drive and heating are switched on
(welding process and data recording).
The device is not in the welding
process.
36
briefly.
to select "Data Recording" and press "e-Drive"
to select "0" and press "e-Drive"
Duration of power
supply interruption
Force:
• If the force falls below the minimum alarm value,
- the force display will flash.
- a "<" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.
• If the force exceeds the maximum alarm value,
- the force display will flash.
- a ">" symbol will be displayed in front of the actual value.
- a warning signal will sound if the acoustic alarm is activated.
to select the Settings menu
briefly.
to select the symbol "Return to working display"
Condition of device after
power supply interruption
The device continues running without
restart protection with the same settings as
before the interruption.
≤ 5 sec
Data recording continues and the data is
added to the file that was created before
the power supply was interrupted.
The device starts up and the start display
appears on the display.
> 5 sec
The welding data that was recorded before
the interruption is contained in the log file.
The device starts up and the start display
appears on the display.
.
and pressing it briefly.
briefly.
.