Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Generator defective
• Storage electronic defective
• Battery (Emergency power supply) empty
• Hands not in detection zone
• Cleaning mode activated
Indicator lamp in the
• Generator defective and battery almost
sensor system flashes
empty (Fitting is supplied by emergency
power)
• Storage electronic defective and battery
almost empty (Fitting is supplied by
emergency power)
Indicator lamp in storage
• Plug-in connector without contact
electronic does not light
while the water flow
• Generator defective
Indicator lamp in storage
• Storage electronic defective
electronic flashes while
the water flow
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose dirty
• Water supply restricted
Remedy
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check 4 plug-in connectors
- Replace generator
- Replace storage electronic
- Replace battery housing
- Hold hands directly under the spout
- Terminate cleaning mode prematurely or wait
3 minutes
- Replace generator and battery housing
- Replace storage electronic and battery housing
- Check plug-in connection between generator
and storage electronic
- Replace generator and battery housing
- Replace storage electronic and battery housing
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control
(special accessory, Prod. No.: 36 206)
- Wait 1 - 10 minutes or deactivate automatic
flushing, see programme table
- Clean or replace mousseur
- Clean filter
- Clean or replace filter
- Check supply lines, open shut-off valve
8