GB
Application/function
Generator-powered single-hole mixer suitable for:
• direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Operation with unpressurised storage heaters
(= displacement water heaters) is not possible.
The Powerbox transforms the energy, that is generated
through the water flow, into electrical energy and stores this.
From 6 water flows with a duration of 10 s daily, the fitting can
be operated energy self-sufficient.
Safety notes
• Installation is only possible in frost-free rooms.
• The generator must not be cleaned with compressed air.
• Use only genuine replacement parts and accessories. The
use of other parts will result in voiding of the warranty and
the CE identification.
Technical data
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
If static pressure exceeds 0.5 MPa, a pressure-reducing valve
must be fitted.
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy saving):
• Electrical storage designed for energy self-sufficient
operation:
- operating time after 10 s water flow:
- operating time after 260 s water flow:
• Emergency power supply:
6V lithium battery type CR-P2
• Automatic safety shut-off
(6 - 420 s adjustable):
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card, grey side,
8x10", landscape (7 - 20cm adjustable):
• Type of protection
- Fitting:
- Powerbox:
General functions of the fitting
• Thermal disinfection:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
The remaining battery capacity is not readable.
Further pre-set programmes can be selected via the sensor
system, see the programme table on page 7.
Special accessories
Further settings and special functions are available via the
infrared remote control (Prod. No. 36 206).
5
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawing on fold-out page I.
Fasten fitting to wash basin, see Figs. [1].
Connect Powerbox
Remove cover from Powerbox, see Fig. [2].
- Fasten Powerbox to wall and connect via enclosed hose to
0.05 MPa
service valve, see Fig. [3] and [4a].
0.1 - 0.5 MPa
- Operation with premixed water: Fasten Powerbox to wall
max. 1 MPa
and connect with special accessory (Prod. No. 34 487 +
1.6 MPa
47 533) to service valves, see Fig. [3] and [4b].
- Connect Powerbox directly to service valve, see Fig. [4c].
Connect fitting to Powerbox and connect plug-in connectors,
approx. 5.7 l/min
see Fig. [5].
max. 70 °C
60 °C
Open water supply and check connections for
watertightness.
4 h
Initial start
100 h
After making plug-in connection fitting is in setting mode for
3 minutes. After the 3 minutes the fitting is ready for operation
and the continuous operation can be performed.
60 s
1 s
Performing continuous operation to load the storage.
1. Hold finger against the lower area of the sensor system,
13cm
Indicator lamp in the sensor system signals:
IP 59K
IP 44
█████████████████████ ██ ██ ██ ██ ██ ██ ██ ▌▌▌▌▌
2.
Remove finger from the sensor system while
activatable
The fitting starts the continuous operation.
While the continuous operation the indicator lamp in the
activatable
storage electronics must light, see Fig. [7]. Otherwise see
deactivated
table Fault/Cause/Remedy page 8.
3.5 min
During the continuous operation the sensor system must not
detect an object. Otherwise the water stops flowing
immediately and the fitting is closed (indicator lamp in the
Closure of the fitting ends automatically after 3 minutes or
can be prematurely terminated (see Terminating cleaning
mode). The continuous operation must be performed again.
Install cover to Powerbox, see Fig. [8].
see Fig. [6].
is displayed.
sensor system starts to flash).
▌▌▌▌