Troubleshooting (cont'd)
If certain problems arise with the tool, an error code
appears on the LCD screen (see pg. 14).
Error
Meaning
Code
1
Overcurrent fuse
2
Overcurrent comparator
3
Overheated circuit board
4
Overheated battery
Battery empty; operation
5
stops
Faulty crimp; complete
6
cycle
Faulty crimp; incomplete
7
cycle
8
Low battery
9
Battery empty
Real-time clock battery
10
low
11
Tool deactivated
12
Service necessary
Real-time clock not
13
found
14
Bluetooth
unit not found
®
15
[Not Used]
Pressure sensor not
16
found
17
Burst pressure exceeded
Battery temperature too
18
low
Blinking Screen 4,750
19
cycles exceeded
Greenlee Tools, Inc.
Gator
Insulated Battery-Powered Inline Cutters
®
LED Indicator (red)
This tool is equipped with a special circuit board
incorporating several important features to inform
the user about the current status of the unit. The LED
signals in the following cases:
Action
Seek Service
Seek Service
Tool will not start,
Cool Tool
and constant light for
20 seconds when trigger
Cool Battery
is released
Charge Battery
Tool will stop, and
constant light for
20 seconds after trigger
Seek Service
is released
Seek Service
Tool will stop, and
flashing light for
Charge Battery
20 seconds when
Charge Battery
trigger is released
Seek Service
Flashing light for 20
Seek Service
seconds at end of cycle
Seek Service
1. Re-insert Battery
2. Seek Service
Note: The tool will indicate when re-certification is near.
1. Re-insert Battery
2. Seek Service
Starting at 4,750 cycles or 21 months (whichever occurs
first), the red LED and work LED will flash, an audible
warning will sound, and the LED will display SERVICE
Seek Service
NECESSARY for 20 seconds after every cutting
operation. After 5,000 cycles or 2 years, the tool will not
Seek Service
operate unless the battery is removed and reinstalled.
Only one cutting operation is possible each time the
Warm Battery
battery is reinstalled.
Seek Service
17
What happens
Signal
and
audible
warning
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
What to
What it means
do
Change
Battery
or charge
charge low
battery
Motor current
exceeds 20 A
Let tool
during cycle
cool
Circuit has
become too hot
Indicates 4,750
Send tool
cycles exceeded
in for
or 21 months
service
exceeded