CARE AND MAINTENANCE
4. Replace the BLUETOOTH
Turn on power source.
TROUBLESHOOTING
PROBLEM
The fan seems louder than
it should
The fan is not
clearing the room
Device will not pair
speaker and grille.
®
POSSIBLE CAUSE
CFM too great
Damper not working properly or damaged
Bend in duct too close to fan discharge
Fan discharge reduced to fit smaller duct
Fan body not securely attached
Insufficient intake airflow within room
Insufficient CFM
Another device is already paired.
4
CORRECTIVE ACTION
Be sure the CFM rating on the fan matches the
size of your room.
Check damper to ensure it is opening and closing
properly. If the damper has become damaged,
please call Customer Service.
Be sure you do not have any sharp bends in duct
closer than 18 in. to the fan discharge.
Use recommended size ducting to reduce fan
noise.
Be sure the fan is securely attached to your ceiling
joists.
Be sure a door or window is slightly ajar or opened
to allow airflow. The fan is not able to draw air out of
the room without enough airflow to draw from.
Be sure the CFM rating on the fan matches the
requirements for your room size.
NOTE: Using a tissue is not an accurate method
for determining if the fan is operating properly. If the
fan clears steam from the room
within approximately 15 minutes of completing your
shower, then the fan is operating properly.
Make sure BLUETOOTH
other devices.
12
®
signal is turned off on
www.homewerksww.com