TECHNICAL CHARACTERISTICS
KEY TIPE
TC 301 Z XY
Y = low temperature operation NT – if there is no sign, there is no low temperature
X = installed heater G – if there is no sign, there is no heater
Heat pump with an integrated aggregate and one exchanger
Type
Use profile
Energy efficiency class
1)
Energy efficiency of water heating
Annual electrical energy consumption
Daily electrical energy consumption
Set thermostat temperature
Level of indoor sound power
3)
Smart value
Storage volume
Mixed water at 40 °C V40
2)
Potential safety measures
(assembly, installation, maintenance)
Technical characteristics
Heating time A15 / W10-55
4)
Heating time A7 / W10-55
5)
Energy consumption in the selected cycle of emissions
A15 / W10-55
4)
Energy consumption in the selected cycle of emissions
A7 / W10-55
5)
COP
A15/W10-55
4)
DHW
COP
A7/W10-55
5)
DHW
Power in standby mode
5)
Refrigerating agent
Quantity of refrigerant
Global Warming Potential
Carbon dioxide equivalent
Operation area regular model
Operation area NT
6)
Area of airflow
Max acceptable pressure drop in the pipeline
(volumetric flow rate of a at 330 m
Electrical characteristics
Specified power of the compressor
Heater power X
7)
Maximum connection power without heater/with heater
Voltage
Electrical protection
Moisture protection
Water tank
Anti-corrosion protection of tank
Nominal pressure
The highest water temperature heat pump
The highest water temperature electrical heater
Connection measurements
Total height
Width
Depth
Inlet/outlet water connections
Inlet/outlet air connection dimensions
Heating area PT - bottom
Heating area PT - top
Exchanger connectors
Weight/Filled with water
The temperature of the heating medium in the heat exchanger
Transport data
Packaging
directive 812/2013, 814/2013, EN16147:2011. Average climate conditions
1)
in accordance with EN16147:2011
2)
3)
in accordance with EN12102:2013 (60% fan speed – outside air/40% fan speed – ambient air)
inlet air temperature 15°C, 74% humidity, water temperature between 10 and 55°C in accordance with EN16147:2011
4)
inlet air temperature 7°C, 89% humidity, water temperature between 10 and 55°C in accordance with EN16147:2011
5)
low temperature mode, stated with the typical sign NT - if there is no sign, there is no low temperature operation
6)
installed heater, stated with the typical sign G - if there is no sign, there is no heater
7)
22
η
wh
%
1)
kWh
1)
1)
kWh
°C
dB (A)
l
l
h:min
h:min
kWh
kWh
W
kg
t
°C
°C
m
/h
3
Pa
/h) (60%)
3
W
W
W
V/Hz
A
MPa
°C
°C
7)
mm
mm
mm
mm
m
2
m
2
kg
°C
mm
TC 200 Z XY
TC 201 Z XY
TC 300 Z XY
L
L
A+
A+
128,5
127,0
797
806
3,762
3,813
55
55
59/58
59/58
0
0
208,0
194,0
260
248
Compulsory use of a safety valve with the pressure connection.
05:21
05:13
06:24
06:06
3,71
3,86
3,82
3,97
3,25
3,12
3,10
3,06
24
26
R134a
R134a
1,100
1,100
1430
1430
1,573
1,573
7 ÷ 35
7 ÷ 35
-7 ÷ 35
-7 ÷ 35
220-450
220-450
100
100
490
490
2000
2000
490/2490
490/2490
230/50
230/50
16
16
IP24
IP24
Enamelled / Mg Anode
0,6/0,9/1,0
0,6/0,9/1,0
65
65
75
75
1540
1540
670
670
690
690
G1
G1
Ø160
Ø160
/
1,45
/
/
-
G1
104/116/312
133/145/327
123/135/418
/
5 ÷ 85
800x800x1765 800x800x1765 800x800x2155 800x800x2155 800x800x2155
TC 301 Z XY
TC302 Z XY
XL
XL
A+
A+
136,0
134,4
1231
1246
5,707
5,787
55
55
59/58
59/58
0
0
295,0
276,0
395
368
08:32
08:00
09:40
09:39
5,75
5,75
5,80
5,96
3,42
3,38
3,34
3,30
18
20
R134a
R134a
1,100
1,100
1430
1430
1,573
1,573
7 ÷ 35
7 ÷ 35
-7 ÷ 35
-7 ÷ 35
220-450
220-450
220-450
100
100
490
490
2000
2000
490/2490
490/2490
490/2490
230/50
230/50
16
16
IP24
IP24
0,6/0,9/1,0
0,6/0,9/1,0
0,6/0,9/1,0
65
65
75
75
1960
1960
670
670
690
690
G1
G1
Ø160
Ø160
/
2,7
/
/
-
G1
177/189/453
173/185/449
/
5 ÷ 85
XL
A+
134,4
1247
5,785
55
59/58
0
276,0
368
08:00
09:39
5,75
5,96
3,38
3,30
20
R134a
1,100
1430
1,573
7 ÷ 35
-7 ÷ 35
100
490
2000
230/50
16
IP24
65
75
1960
670
690
G1
Ø160
1,6
1,0
G1