and closing cycle, or previously disable deceleration (see
function C7), so that when programming motor time, the
deceleration phase will be automatically excluded.
During programming the radio control key of the control
unit can be used instead of the SET key, if stored
previously.
A8) PAUSE T.:
(Automatic closing time programming max. 4
minutes)
The control unit is supplied by the manufacturer without
automatic closing. If you want to enable automatic
closing, proceed as follows: set SEL and SET to display
A8 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET briefly and also
DOT 2 will start to flash. At the same time, the Display will
scan the Pause time seconds to Memorise, wait for the
time desired; briefly press the SET key again, DOT 2 will
remain lit permanently and simultaneously memorise the
automatic closing time.
If you want to restore the original status (without
automatic closing), set SEL and SET to display A8, then
press SET to select the function. At the same time, DOT 1
will start to flash, press SET for a few seconds, DOT 1
and DOT 2 will go off and the procedure will be complete.
A9 ) T. RIT. ANTE :
(Programming door delay of 15 sec.
Max.)
The control unit is supplied by the manufacturer without
gate delay during opening and closing. If automation
configuration is used with 2 motors, it may be necessary
to enter the door delay time; follow this procedure for
programming with the shutter closed:
set SEL and SET to display A9 then press SET to select
the function. At the same time DOT 1 will start to flash,
press SET briefly and also DOT 2 will start to flash. At the
same time, the Display will scan the Doors Closing Delay
time seconds, wait for the time desired; briefly press the
SET key again, DOT 2 will remain lit permanently and
simultaneously memorise the Opening Doors Delay time
fixed at 2 seconds, the Doors Closing Delay time for the
programmed time.
If you want to restore the original status (without and Door
Delay), set SEL and SET to display A9, then press SET to
select the function. At the same time, DOT 1 will start to
flash, press SET for a few seconds, DOT 1 and DOT 2 will
go off and the procedure will be complete.
Attention: If previously selected the 1 Motor operating mode,
the selection of the delay time is disabled.
CONFIGURATIONS MENU " B "
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
----------------- CONFIGURATIONS MENU " B " --------------
Digit Reference
B1) OPENING CMD INB.
B2) AUTOMATIC OPERATION
B3) WATER HAMMER
B4) CLOSING HAMMER
B5) FOLLOW ME
B6) REMOTE TX PGM
B7) ELECTRONIC BRAKE
B8) SOFT START
B9) SOFT STOP
B1) OPENING CMD. INB. (Opening command inhibition):
The command inhibition function during opening is used, for
example, when automation includes a loop detector. During the
opening or pause phase, the control unit does not respond to
commands sent by the loop detector with every passage.
The control unit is supplied by the manufacturer with the
Opening Command Inhibition function disabled. If you want to
enable the function, proceed as follows: set SEL and SET to
display B1 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET to change the function,
DOT 2 will remain permanently lit and the operation will be
complete.
Repeat the procedure to restore the previous configuration.
B2) OPERATION (Automatic / Step-step):
The default settings of the control unit have "Automatic"
operating logic. If you want to select "Step-Step" operating
mode, proceed as follows: set SEL and SET to display B2 then
press SET to select the function. At the same time DOT 1 will
start to flash, press SET to change the function, DOT 2 will
remain permanently lit and the operation will be complete.
Repeat the procedure to restore the previous configuration.
B3) WATER HAMMER:
The control unit is supplied by the manufacturer with Water
Hammer disabled. If you want to enable the Water Hammer
function at maximum power, proceed as follows: set SEL and
SET to display B3 then press SET to select the function. At the
same time DOT 1 will start to flash, press SET to change the
function, DOT 2 will remain permanently lit and the operation
will be complete.
If, however, you want to enable the Water Hammer function
with the force set via trimmer VR2, proceed as follows: set SEL
and SET to display B3 then press SET to select the function. At
the same time DOT 1 will start to flash, press SET and at the
same time DOT 1 will start to flash quickly, press SET to
change the function, DOT 2 will remain permanently lit and the
operation will be complete.
Repeat the operation to restore the initial configuration.
Accordingly, we can facilitate the release of the gate and
therefore allow the proper execution of the opening phase. In
fact, the control unit, before starting the opening phase sends a
closing command for 2 seconds with power relative to the
choice selected.
13
DOT 2 Off
DOT 2 On
NO
YES
STEP/STEP
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
Rev. 1.1